In vitro comparison of primary stability of two implant designs in D3 bone

نویسندگان

  • José González-Serrano
  • Ricardo Ortega-Aranegui
  • Juan López-Quiles
چکیده

BACKGROUND Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). MATERIAL AND METHODS A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer's guidelines. Osstell™ and Periotest® devices were used to evaluate PS by a blinded independent observer. Computed tomographies (CTs) of the ribs were made (BrightSpeed Series CT systems, GE Healthcare, Milwaukee, WI, USA) and bone quality surrounding each implant was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Korea). Bone quality was classified according to Misch and Kircos in D1, D2, D3 or D4. RESULTS All implants were mechanically stable. Only implants placed in D3 bone (350-850 HU) were selected for the study: 28 PHI and 26 PHIA. The one way ANOVA showed significant difference (p < 0.005) among two implants designs in ISQ values (61,55 ± 6,67 in PHI and 68,94 ± 5,82 in PHIA). No significant difference (p = 0,171) was shown in PV between two designs (-4,47 ± 1,39 in PHI and -4,77 ± 0,87 in PHIA). CONCLUSIONS Higher PS was found using Osstell™ device in implants with double thread design (PHIA) in comparison to implants with single thread design (PHI) in D3 bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

The Effect of Implant Length and Diameter on the Primary Stability in Different Bone Types

OBJECTIVE The focus of this paper is to evaluate the influence of mechanical characteristics of the implant on primary stability in different bone types, based on resonance frequency analysis (RFA). MATERIALS AND METHODS A number of 60 Nobel Biocare Replace Select TiUnit Tapered implants of two different lengths (10 mm and 13 mm) and three different widths as 3.4 mm (narrow platform (NP)), 4....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2017