PI and PID Parameters from IMC Designs
ثبت نشده
چکیده
منابع مشابه
A Unified IMC based PI/PID Controller Tuning Approach for Time Delay Processes
This paper proposes a new PI/PID controller tuning method within filtered Smith predictor (FSP) configuration in order to deal with various types of time delay processes including stable, unstable and integrating delay dominant and slow dynamic processes. The proposed PI/PID controller is designed based on the IMC principle and is tuned using a new constraint and without requiring any approxima...
متن کاملExtension of IMC tuning correlations for non-self regulating (integrating) processes.
The filter term of a PID with Filter controller reduces the impact of measurement noise on the derivative action of the controller. This impact is quantified by the controller output travel defined as the total movement of the controller output per unit time. Decreasing controller output travel is important to reduce wear in the final control element. Internal Model Control (IMC) tuning correla...
متن کاملNonlinear Internal Model Control for Miso Systems Based on Local Linear Neuro-fuzzy Models
The internal model control (IMC) scheme has been widely applied in the field of process control. So far, IMC has been mainly applied to linear processes. This paper discusses the extension of the IMC scheme to nonlinear processes based on local linear models where the properties of linear design procedures can be exploited. The IMC scheme results in controllers that are comparable to gain-sched...
متن کاملIMC based automatic tuning method for PID controllers in a Smith predictor configuration
In this paper, a new approach is presented based on relay autotuning of a plant to find parameters for its control using a Smith predictor. A Smith predictor configuration is represented as its equivalent internal model controller (IMC) which provides the parameters of the proportional-integral (PI) or proportional-integral-derivative (PID) controller to be defined in terms of the desired close...
متن کاملClosed-loop model identification and PID/PI tuning for robust anti-slug control
Active control of the production choke valve is the recommended solution to prevent severe slugging flow at offshore oilfields. This requires operation in an open-loop unstable operating point. It is possible to use PI or PID controllers which are the preferred choice in the industry, but they need to be tuned appropriately for robustness against plant changes and large inflow disturbances. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002