The impact of statistical choices on neonatal intensive care unit quality ratings based on nosocomial infection rates.
نویسندگان
چکیده
OBJECTIVE To examine the extent to which performance assessment methods affect the percentage of neonatal intensive care units (NICUs) and very low-birth-weight (VLBW) infants included in performance assessments, the distribution of NICU performance ratings, and the level of agreement in those ratings. DESIGN Cross-sectional study based on risk-adjusted nosocomial infection rates. SETTING NICUs belonging to the California Perinatal Quality Care Collaborative 2007-2008. PARTICIPANTS One hundred twenty-six California NICUs and 10 487 VLBW infants. MAIN EXPOSURES Three performance assessment choices: (1) excluding "low-volume" NICUs (those caring for <30 VLBW infants per year) vs a criterion based on confidence intervals, (2) using Bayesian vs frequentist hierarchical models, and (3) pooling data across 1 vs 2 years. MAIN OUTCOME MEASURES Proportion of NICUs and patients included in quality assessment, distribution of ratings for NICUs, and agreement between methods using the κ statistic. RESULTS Depending on the methods applied, 51% to 85% of NICUs and 72% to 96% of VLBW infants were included in performance assessments, 76% to 87% of NICUs were considered "average," and the level of agreement between NICU ratings ranged from 0.23 to 0.89. CONCLUSIONS The percentage of NICUs included in performance assessments and their ratings can shift dramatically depending on performance measurement method. Physicians, payers, and policymakers should continue to closely examine which existing performance assessment methods are most appropriate for evaluating pediatric care quality.
منابع مشابه
عفونتهای بیمارستانی و عوامل باکتریایی آنها: بخش مراقبتهای ویژه نوزادان بیمارستان دانشگاهی قائم (عج) مشهد
Background: Nosocomial infections increase patients' morbidity, mortality and length of hospital stay especially in neonatal intensive care units (NICUs) and have become a matter of major concern. Controlling and preventing nosocomial infections need enough information about epidemiology of these infections. This study aims at estimating the incidence rate and the most frequent bacteria which c...
متن کاملAssessment of Knowledge of the Medical staff (Residents and Nurses) In Nosocomial infections in NICU in Mashhad
Introduction: Nosocomial Infections (NI) are frequent and relevant problem and it is responsible for mortality especially in pediatric ICU and NICUs. Healthcare- associated infections are of important wide-ranging concern in the medical field. In the neonatal intensive care unit population the Nosocomial infection rate is highest in the lowest-birth-weight infants. It is this group of infants w...
متن کاملThe Study of Nosocomial Infections in Neonatal Intensive Care Unit, A prospective study in Northwest Iran
Background: Nosocomial infections are an important cause of mortality in neonatal intensive care units (NICUs). Therefore, in this study, the incidence and prevalence of nosocomial infections were determined in NICUs of the three largest neonatal centers in northwest Iran, and the causative bacteria were identified in order to provide potential solutions to control the infections in these hospi...
متن کاملEvaluation and development of potentially better practices to prevent neonatal nosocomial bacteremia.
OBJECTIVE Six neonatal intensive care units (NICUs) that are members of the Vermont Oxford National Evidence-Based Quality Improvement Collaborative for Neonatology collaborated to reduce infection rates. There were 7 centers in the original focus group, but 1 center left the collaborative after 1 year. The objective of this study was to develop strategies to decrease nosocomial infection rates...
متن کاملStudy of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit
Mobile phones and stethoscopes used in neonatology units could be colonized by potentiel bacteria pathogens. It can be a vector of severe nosocomial infections and multi-drug-resistant pathogens. The aim of this study is to evaluate the microbial contamination of mobile phones and stethoscopes, used by medical and paramedical staff. The study was conducted in neonatal intensive care unit (NICU)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of pediatrics & adolescent medicine
دوره 165 5 شماره
صفحات -
تاریخ انتشار 2011