Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements.

نویسندگان

  • Kenji Yoshitani
  • Masahiko Kawaguchi
  • Norikazu Miura
  • Takashi Okuno
  • Tomoko Kanoda
  • Yoshihiko Ohnishi
  • Masakazu Kuro
چکیده

BACKGROUND Previous studies documented that near-infrared spectroscopy values were affected by factors related to optical path length, such as hemoglobin concentration, the differential path length factor, skull thickness (t-skull), and the area of the cerebrospinal fluid layer (a-CSFL). Lately, the NIRO-100 (Hamamatsu Photonics, Hamamatsu, Japan) has provided a tissue oxygen index (TOI) that theoretically is not supposed to be affected by optical path length. Therefore, the authors hypothesized that TOI is not influenced by the above-described individual factors. METHODS Cardiac surgical or neurosurgical 103 patients (65 men and 39 women; aged 63 +/- 14 yr) were studied. TOI and regional cerebral oxygen saturation (rSO2) (INVOS 4100; Somanetics, Troy, MI) were measured sequentially on patients in a resting state. The t-skull and a-CSFL were calculated using computed tomographic image slices of the head corresponding with the position of near-infrared spectroscopy sensors. The effects of these two factors, hemoglobin concentration and mean arterial pressure, on TOI and rSO2 values were evaluated by linear regression analysis. RESULTS Simple linear regression analysis showed that mean arterial pressure (r = 0.27, P = 0.008), t-skull (r = 0.22, P = 0.034), a-CSFL (0.26, P = 0.012), and hemoglobin concentration (r = 0.42, P < 0.0001) were significant determinants of rSO2. Multiple linear regression analysis showed that hemoglobin concentration (r = 0.34, P < 0.001), a-CSFL (r = -0.252, P = 0.012), and t-skull (r = 0.22, P = 0.037) were significant determinants of rSO2. On the other hand, simple and multiple linear regression analysis showed that there was no significant determinant of TOI. CONCLUSION rSO2 values were affected by hemoglobin concentration, a-CSFL, and t-skull, but TOI values were not affected by individual factors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-infrared light propagation in an adult head model. II. Effect of superficial tissue thickness on the sensitivity of the near-infrared spectroscopy signal.

It is important for near-infrared spectroscopy (NIRS) and imaging to estimate the sensitivity of the detected signal to the change in hemoglobin that results from brain activation and the volume of tissue interrogated for a specific source-detector fiber spacing. In this study light propagation in adult head models is predicted by Monte Carlo simulation to investigate the effect of the superfic...

متن کامل

Correlation between skin, bone, and cerebrospinal fluid layer thickness and optical coefficients measured by multidistance frequency-domain near-infrared spectroscopy in term and preterm infants.

Near-infrared spectroscopy (NIRS) is increasingly used in neonatal intensive care. We investigated the impact of skin, bone, and cerebrospinal fluid (CSF) layer thickness in term and preterm infants on absorption-(μa) and/or reduced scattering coefficients (μs') measured by multidistance frequency-domain (FD)-NIRS. Transcranial ultrasound was performed to measure the layer thicknesses. Correlat...

متن کامل

Optical Characterization of Two-Layered Turbid Media for Non-Invasive, Absolute Oximetry in Cerebral and Extracerebral Tissue

We introduce a multi-distance, frequency-domain, near-infrared spectroscopy (NIRS) method to measure the optical coefficients of two-layered media and the thickness of the top layer from diffuse reflectance measurements. This method features a direct solution based on diffusion theory and an inversion procedure based on the Levenberg-Marquardt algorithm. We have validated our method through Mon...

متن کامل

Near-infrared light propagation in an adult head model. I. Modeling of low-level scattering in the cerebrospinal fluid layer.

Adequate modeling of light propagation in a human head is important for quantitative near-infrared spectroscopy and optical imaging. The presence of a nonscattering cerebrospinal fluid (CSF) that surrounds the brain has been previously shown to have a strong effect on light propagation in the head. However, in reality, a small amount of scattering is caused by the arachnoid trabeculae in the CS...

متن کامل

Change of Hemoglobin Concentration with nano particles can predict breast cancer using near infrared source?

Introduction: Early detection and treatment of breast cancer may be helping to save the lives of patients. Many new techniques have been urban to detect breast cancer. One of them is the use of nano-particles for accuracy and early diagnosis after photo transfer. In this study, rod gold nano particles was used according their ability to change light source transfer intensity. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 106 3  شماره 

صفحات  -

تاریخ انتشار 2007