Technical Note: Using a high finesse optical resonator to provide a long light path for differential optical absorption spectroscopy: CE-DOAS

نویسندگان

  • J. Meinen
  • T. Leisner
چکیده

Cavity enhanced methods in absorption spectroscopy have seen a considerable increase in popularity during the past decade. Especially Cavity Enhanced Absorption Spectroscopy (CEAS) established itself in atmospheric trace gas detection by providing tens of kilometers of effective light path length using a cavity as short as 1 m. In this paper we report on the construction and testing of a compact and power efficient light emitting diode based broadband Cavity Enhanced Differential Optical Absorption Spectrometer (CE-DOAS) for in situ observation of atmospheric NO3. This device combines the small size of the cavity with the advantages of the DOAS approach in terms of sensitivity, specificity and insensivity to intensity fluctuations of the light source. In particular, no selective removal of the analyte (here NO3) is necessary for calibration of the instrument if appropriate corrections are applied to the CEAS theory. Therefore the CE-DOAS technique can – in principle – measure any gas detectable by DOAS. We will discuss the advantages of using a light emitting diode (LED) as light source particularly the precautions which have to be considered for the use of LEDs with a broad wavelength range. The instrument was tested in the lab by detecting NO3 formed by mixing of NO2 and O3 in air. It was then compared to other trace gas detection techniques in an intercomparison Correspondence to: J. Meinen ([email protected]) campaign in the atmosphere simulation chamber SAPHIR at Forschungszentrum Jülich at NO3 concentrations as low as 6.3 ppt.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High finesse optical resonators for DOAS measurements

Using a high finesse optical resonator to provide a long light path for differential optical absorption spectroscopy: CE-DOAS J. Meinen, J. Thieser, U. Platt, and T. Leisner Institute for Meteorology and Climate Research, Aerosols and Heterogeneous Chemistry in the Atmosphere (IMK-AAF), Forschungszentrum Karlsruhe GmbH, Germany Institut for Environmental Physics (IUP), Atmosphere and Remote Sen...

متن کامل

Using a high finesse optical resonator to provide a long light path for differential optical absorption spectroscopy: CE-DOAS

Cavity enhanced methods in absorption spectroscopy have seen a considerable increase in popularity during the past decade. Especially Cavity Enhanced Absorption Spectroscopy (CEAS) established itself in atmospheric trace gas detection by providing tens of kilometers of effective light path length using a cavity as short as 1 m. In 5 this paper we report on the construction and testing of a comp...

متن کامل

MAX-DOAS O4 measurements – a new technique to derive information on atmospheric aerosols

Multi AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) observations of the oxygen dimer O4 are presented which can serve as a new method for the determination of atmospheric aerosol properties. Like established methods e.g. sun radiometer and LIDAR measurements MAX-DOAS O4 observations determine optical properties of aerosol under atmospheric conditions (not dried). However, the nov...

متن کامل

Differential optical absorption spectroscopy system used for atmospheric mercury monitoring.

A high-resolution differential optical absorption spectroscopy (DOAS) system for long-path atmospheric pollution monitoring is described. The system, consisting of a broadband lamp and a dispersive, fast-scanning optical receiver, separated by a few kilometers, was used in measurements of different pollutants, highlighted by the monitoring of the local concentration of atomic mercury. Mercury l...

متن کامل

Long-path measurement of atmospheric NO2 with an obstruction flashlight and a charge-coupled-device spectrometer.

A novel method of differential optical absorption spectroscopy (DOAS) is proposed and demonstrated to monitor the concentration of atmospheric pollutant gas. In contrast to conventional DOAS measurements with continuous light sources, the present method relies on white flashlights such as aviation obstruction lights that are generally installed on tall constructions. A simple detection system i...