Toward New Engagement Paradigms For Intraocular Lenses: Light-Initiated Bonding of Capsular Bag to Lens Materials.
نویسندگان
چکیده
PURPOSE Successful intraocular lens procedures, that is, implantation of accommodating intraocular lenses (A-IOL), require firm engagement of the IOL haptics to the capsular bag. We evaluated the use of photochemical bonding to engage IOL materials to the capsular bag. METHODS Freshly enucleated eyes of New Zealand rabbits were used in two types of photobonding experiments using Rose Bengal (RB) photoinitiation and green light (532-nm) irradiation. First, RB-stained capsular bag strips were photobonded ex vivo to IOL polymer [poly(2-hydroxyethyl methacrylate) pHEMA] strips in an atmosphere of air and of nitrogen. Second, IOLs were implanted intracapsularly and photobonded intraocularly. Irradiation times were between 30 and 180 seconds, and laser irradiance was between 0.25 and 0.65 W/cm(2). The strength of the bonding was tested using a custom-developed uniaxial extensiometry system and the breakage load (the load that caused breakage per bonded area) was calculated. RESULTS The breakage load of ex vivo capsule-pHEMA bonds increased exponentially with irradiation time, using 0.45 W/cm(2). In air, the average breakage load across all conditions was 1 g/mm(2) and 1.6 times lower than that in a nitrogen atmosphere. Intraocularly, RB-stained IOLs were strongly photobonded to the capsule bag with breakage loads > 0.8 g/mm(2). CONCLUSIONS Breakage of the photobonded linkage between IOL material and capsular bag required loads substantially greater than the maximum force of ciliary muscle, suggesting that this technology may introduce a new paradigm for engagement of A-IOLs. The bonding produced in air was stronger than that in nitrogen atmosphere, suggesting that oxygen is involved in the chemical mechanism for photobonding.
منابع مشابه
Biocompatibility of Intraocular Lenses
The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in...
متن کاملManagement of subluxated capsular bag-fixated intraocular lenses using a capsular anchor.
UNLABELLED We describe the use of the capsular anchor (AssiAnchor) to manage a subluxated intraocular lens (IOL) in the capsular bag. The anchor comprises 2 prongs that hold the anterior lens capsule and a central rod that is sutured to the scleral wall, enabling centration of the IOL-capsular bag complex. Six pseudophakic patients presenting with subluxated posterior chamber IOLs in the capsul...
متن کاملPosterior chamber intraocular lens implantation--a new forceps to simplify capsular bag fixation.
The case for capsular bag fixation of the Sinsky-Kratz type of posterior chamber intraocular implant lens is presented, and the various methods in use to position implant lenses are outlined. The new forceps are described and the rationale for their adoption and use is given in an illustrated, step-by-step fashion. Their additional use in anterior chamber intraocular lens implantation is mentio...
متن کاملBilateral spontaneous dislocation of intraocular lenses within the capsular bag in a retinitis pigmentosa patient.
A 45-year-old man with retinitis pigmentosa (RP), who had undergone uneventful extracapsular cataract extraction (ECCE) in his right eye eight years previously, and phacoemulsification in his left eye six years previously, had spontaneously dislocated intraocular lenses (IOL) within the capsular bag in both eyes one month apart. We removed the dislocated IOLs, and performed anterior vitrectomy ...
متن کاملA fully human in vitro capsular bag model to permit intraocular lens evaluation.
PURPOSE To establish a fully human in vitro culture model with which to test the putative effects of intraocular lens (IOL) designs in preventing posterior capsule opacification (PCO) after cataract surgery. METHODS A sham cataract operation was performed to prepare human capsular bags from donor lenses. In one capsular bag of a donor pair, an intraocular lens (PMMA round-edge IOL or acrylic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 56 8 شماره
صفحات -
تاریخ انتشار 2015