Resonance Parameters and Uncertainties Derived from Epithermal Neutron Capture and Transmission Measurements of Natural Molybdenum

نویسندگان

  • G. Leinweber
  • D. P. Barry
  • J. A. Burke
  • N. J. Drindak
  • N. C. Francis
  • B. E. Moretti
چکیده

The electron linear accelerator facility at the Rensselaer Polytechnic Institute was used to explore neutron interactions with molybdenum in the energy region from 10 eV to 2 keV. Neutron capture and transmission measurements were performed by the time-of-flight technique. Resonance parameters were extracted from the data using the multilevel R-matrix Bayesian code SAMMY. A table of resonance parameters and their uncertainties is presented. Two transmission measurements were performed at a flight path of 25 m with a 6Li glass scintillation detector. The neutron capture measurements were performed at a flight path of 25 m with a 16-segment sodium iodide multiplicity detector. Nine different thicknesses of elemental molybdenum metal samples ranging from 0.051 mm (0.002 in.) to 6.35 mm (0.250 in.) were measured in either capture or transmission. Reductions in resonance integrals were observed when compared to ENDF/B-VII.0 for six of the seven stable isotopes. The largest reductions were 9% in 97Mo and 11% in 100Mo. The one measured increase in resonance integral relative to ENDF/B-VII.0 occurred in 95Mo, and it was significant (10%). The measured distribution of neutron widths for 95Mo and 97Mo are a better match to a Porter-Thomas distribution than those of ENDF/B-VII.0. Neutron strength functions for 95Mo and 97Mo were measured and compared to ENDF/B-VII.0. The strength of 95Mo and 97Mo are within uncertainties of each other. The measured radiation width distribution for 95Mo and 97Mo are compared to those of ENDF/B-VII.0 and to x2 distributions. Significant aspects of this analysis are the assignment of radiation widths, the determination of the transmission resolution function, and the propagation of experimental uncertainties into resonance parameter uncertainties.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium

Epithermal neutron capture and transmission measurements were performed using the timeof-flight method at the Rensselaer Polytechnic Institute linac using metallic Nb samples. The capture measurements were made at the 25-m flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-m flight station with a 6Li glass scintillation detector. Res...

متن کامل

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Neodymium neutron cross section measurements.

Neutron capture and transmission measurements were performed by the time-of-flight technique at the Rensselaer Polytechnic Institute LINAC using metallic neodymium samples. The capture measurements were made at the 25-m-long flight station with a 16-segment NaI(Tl) multiplicity detector, and the transmission measurements were performed at 15 and 25 m flight stations with a 6Li glass scintillati...

متن کامل

Neutron Capture Measurements and Resonance Parameters of Gadolinium

Abstract – Neutron capture measurements were performed with the time-of-flight method at the Gaerttner LINAC Center at Rensselaer Polytechnic Institute (RPI) using isotopically enriched gadolinium (Gd) samples (Gd, Gd, Gd, Gd, and Gd). The neutron capture measurements were made at the 25-m flight station with a 16-segment sodium iodide multiplicity detector. After the data were collected and re...

متن کامل

Neutron transmission and capture measurements and analysis of Dy from 0.01 to 550eV

Neutron capture and transmission measurements were carried out from 0.01 to over 600 eV on both natural Dy and samples highly enriched in 164Dy. These data were analyzed for resonance parameters utilizing the SAMMY Bayesian analysis code to simultaneously fit both the capture and transmission data. Parameters were obtained for 17 resonances in Dy isotopes up to 18 eV and for the 164Dy resonance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010