Concanavalin A-bound selenoprotein in human serum analyzed by graphite furnace atomic absorption spectrometry.

نویسندگان

  • R Daher
  • F Van Lente
چکیده

We developed an assay for the direct determination of selenium in serum with a Perkin-Elmer Model 4100ZL Zeeman atomic absorption spectrometer and Ag-Cu-Mg modifier. We used this assay to analyze concanavalin A-bound selenoprotein (CABSP) in human serum after concanavalin A (ConA) affinity chromatography. The CABSP was identified as a single-chain glycoprotein of 57.3 kDa. Carbohydrate units were N- and O-linked to the protein. The selenium moiety was selenocysteine. Total selenium, glutathione peroxidase (GPX; EC 1.11.1.9), ConA-bound selenium (CABS), and alpha 1-acid glycoprotein (AAG) were determined in normal subjects and patients with various pathological conditions. CABS accounted for 44.1% +/- 6.3% of total selenium in sera from normal subjects and 46.5% +/- 3.9% to 55.1% +/- 8.1% in sera from patients with a variety of diseases. Total selenium in serum was well correlated with serum CABS (r = 0.860), but not with serum GPX activity (r = 0.117), for all patients studied. Serum CABS increased in normal subjects after selenium supplementation. Serum CABSP did not behave as an acute-phase reactant, compared with AAG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Rapid Zeeman atomic absorption determination of copper in serum and urine.

In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modifying the drying and pyrolysis stages of the graphite furnace atomic absorption...

متن کامل

Measurement of cadmium residues in muscle, liver and kidney of cattle slaughtered in Isfahan abattoir using grafite furnace atomic absorption spectrometry (GFAAS): a preliminary study

The aim of the present study was to determine the levels of cadmium in the muscle, liver and kidney of cattle from Isfahan and to compare the results with those reported by other countries and with the maximum acceptable levels for human consumption. Samples of muscle, liver and kidney from 60 animals aged 1–10- year-old were collected from the carcasses slaughtered at Isfahan abattoir. Samples...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

Direct determination of zinc in serum by Zeeman atomic absorption spectrometry with a graphite furnace.

We developed a precise and accurate graphite furnace atomic absorption spectrometric method for the direct determination of zinc in serum. Serum samples are analyzed after 20-fold dilution with water of ultrapure analytical grade. No other reagent is used, from the moment of sampling until measurement. During atomization, the argon flow is kept at 150 mL/min instead of gas stop, to decrease the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 1994