Automated Verification of IGRT‐based Patient Positioning

نویسندگان

  • Xiaojun Jiang
  • Tim Fox
  • James S. Cordova
  • Eduard Schreibmann
چکیده

A system for automated quality assurance in radiotherapy of a therapist's registration was designed and tested in clinical practice. The approach compliments the clinical software's automated registration in terms of algorithm configuration and performance, and constitutes a practical approach for ensuring safe patient setups. Per our convergence analysis, evolutionary algorithms perform better in finding the global optima of the cost function with discrepancies from a deterministic optimizer seen sporadically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Quality Assurance for Image‐Guided Radiation Therapy

The use of image-guided patient positioning requires fast and reliable Quality Assurance (QA) methods to ensure the megavoltage (MV) treatment beam coincides with the integrated kilovoltage (kV) or volumetric cone-beam CT (CBCT) imaging and guidance systems. Current QA protocol is based on visually observing deviations of certain features in acquired kV in-room treatment images such as markers,...

متن کامل

SU-E-J-36: A Flexible Integration of Key Technologies in Image-Guided Radiotherapy for Accurate Radiotherapy System (ARTS-IGRT).

PURPOSE Image-guided radiotherapy (IGRT) is becoming increasingly important in the planning and delivery of radiotherapy. With the aim of implementing the key technologies in a flexible and integrated way in IGRT for accurate radiotherapy system (ARTS), a prototype system named as ARTS-IGRT was designed and completed to apply main principles in image-guided radiotherapy. METHODS The basic wor...

متن کامل

SU-E-J-46: Use of Brainlab-ExacTrac IGRT with Dot-Decimal Electron Compensator(BolusECT) for Accurate Patient Positioning.

PURPOSE To Validate Brainlab-ExacTrac IGRT with Dot-Decimal electron compensator(BolusECT) for accurate patient positioning. METHODS Dot-Decimal electron compensators(BolusECT) are used to achieve conformal dose distributions and greater sparing to normal structures for cases with varying patient contours and treated with single electron beam.Setup for such patients is difficult to verify due...

متن کامل

Delineation of Margins for the Planning Target Volume (PTV) for Image-Guided Radiotherapy (IGRT) of Gastric Cancer Based on Intrafraction Motion

Background: Application of the image-guided radiotherapy (IGRT) system for gastric cancer involving daily verification of patient positioning on the treatment machine allows minimisation of geometrical errors as a consequence of intra- and inter-fraction motion. The purpose of this study was to define the intrafraction motion in gastric cancer patients during a treatment session based on the IG...

متن کامل

Measurement of the immobilisation efficacy of a head fixation system

Background: In order to assign appropriate planning target volume (PTV) margins, each centre should measure the patient positioning deviations for their set-up techniques. At the Royal Marsden Hospital, UK, a conformal shell (cast) system is used when a stereotactic frame is not suitable. In this paper, we report on a series of measurements with the aim of obtaining the systematic and random ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015