Morphology and relationship to extensibility curves of human mitral valve chordae tendineae.

نویسندگان

  • K O Lim
  • D R Boughner
چکیده

Human mitral valve chordae tendineae in which elastic response curves are nonlinear have also been found to exhibit extensibility that increases with chordal size and decreases with chordal age. We used selective enzymatic digestion and scanning transmission electron microscopy to explain these observations. Removal of the outer elastin sheath by enzymatic digestion did not significantly affect the elastic response of this tissue. Scanning electron microscopy revealed that the collagen fibers in the central core of young chordae exhibited a very wavy pattern but the pattern in adult specimens was relatively straight. The increased waviness accounted for the greater extensibility of the young specimens. The collagen fibers from young and old chordae consisted of a network of collagen fibrils that became more collapsed when the tissue was fixed under tension. This network arrangement of the fibrils explains the nonlinearity in the elastic response of the tissue. Transmission electron micrographs showed that the density of collagen fibrils decreased as chordal size increased. The number of fibrils per 10(-8) cm2 of the central core decreased from 182.4 (SE = 1.3) to 131.3 (SE = 1.6) as average chordal cross-sectional area increased from 0.0016 cm2 to 0.0268 cm2. This difference in fibril density provides an explanation for the greater extensibility shown by the thicker chordae. The collagen fibril diameters ranged from 516 A to 552 A.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Papillary fibroelastoma of a mitral valve chordae, presenting with atypical chest pain and palpitation: A case report and the literature

Background: Primary intra cardiac tumors are rare. In this article, we present papillary fibroelastoma of mitral valve chordae. Case Presentation: A 35-year old man presented with atypical chest pain and palpitation. Physical examination and electrocardiogram were normal. Transesophageal echocardiography (TEE) revealed a mass of 1015 mm attached to chordae of anteromedial papillary muscle of ...

متن کامل

A comparative study of the morphology of mammalian chordae tendineae of the mitral and tricuspid valves

It is assumed that the human heart is almost identical to domestic mammalian species, but with limited literature to support this. One such area that has been underinvestigated is that of the subvalvular apparatus level. The authors set out to examine the morphology of the subvalvular apparatus of the mammalian atrioventricular valves through gross dissection and microscopic analysis in a small...

متن کامل

Anomalous Chordae Tendineae Associated with Mitral Valve Dysplasia in a Cat

A rare case of anomalous chordae tendineae associated with mitral valve dysplasia was observed during necropsy in a 5year-old male Persian cat with a history of sudden death. Grossly, there was thickening of the mitral valve, which was connected to numerous, short and thickened chordae tendineae that were ectopically inserted into the myocardium. In addition, marked left atrial dilation and pul...

متن کامل

Morphology of the Human Mitral Valve

Chordae tendineae from 50 normal mitral valves were studied. Four main types can be distinguished by their mode of insertion. Commissural chordae insert into and define the commissures between the anterior and posterior leaflets. Rough zone chordae insert into the ventricular aspect of the distal rough portion of the anterior and posterior leaflets. Such rough zone chordae typically split into ...

متن کامل

Morphological Investigations of the Anterior Leaflet and its Chordae Tendineae in Canine Mitral Valves

Although mitral valve repair (MVR)—for mitral regurgitation (MR) secondary to chronic valvular heart disease (CVHD)— is becoming more common in veterinary medicine, there is little information about the morphology of the mitral valve apparatus that is used to guide veterinary surgeons. Therefore, we investigated the locations of MR using echocardiography in 12 client-owned dogs with MR. Nine (7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 1976