In-vivo Study of Cardiac Pressure-Volume Curves using Implantable RF Telemetry

نویسندگان

  • Kyle Fricke
  • Chad Hodgson
  • Filip Konecny
  • Alexander El-Warrak
  • Heather Cadieux-Pitre
  • Tracy Hill
  • Robert Sobot
چکیده

We present our study of a real-time monitoring methodology of pressure-volume (PV) in-vivo signals generated by our implantable RF telemetry system, where the dual PV sensor is implanted in a heart of a freely moving animal subject. I. THE STUDY OVERVIEW Real-time left ventricular (LV) pressure-volume (PV) loops are one of the main indicators of the myocardium health in animals and humans. Accurate real-time PV data allow researchers to quantify cardiac pathology, e.g., congestive heart failure [1]. Thus, a small catheter that incases both pressure and volume sensors is implanted into the LV of the subject’s heart where the real-time measurements are taken. While blood pressure measurement using MEMS sensors is already established methodology, the blood volume measurements based on conductance catheter methodology is still subject of vigorous theoretical and experimental research [2]. Our system architecture consists of four system level blocks that share a common data and DC power bus: power regulating electronics, signal processing and control unit, RF transceiver, PV sensor interface, and the dual PV sensor itself (provided by Transonic Scisense Inc.). The complete system is encapsulated in a 3D printed custom bio-compatible package suitable for the surgical procedure. Size of the complete wireless PV telemetry system, including the Li–Poly battery, is (15× 15× 11)mm and it weighs 4.0g [4]. The PV wireless telemetry system was evaluated in–vivo using a 60kg swine subject. The study was designed to evaluate the PV system in a non–anaesthetised test subject, i.e., freely moving animal. In addition, the study was completed to evaluate catheter-heart interaction. Prior to surgery, the implant and PV catheter were sterilized. The catheter was inserted into the left ventricle via the carotid artery and the system was implanted and secured in the neck region of the test subject, Fig. 1a. Fluoroscopy was used to assist in the positioning of the catheter and implant within the left ventricle and neck region, Fig. 1b. Data was collected for 48 hours via the RF link from the implant to an external laptop. The implant is designed to transmit raw voltages, thus additional data processing *This work was supported by Transonic London ON, OCE, NSERC, CFI, and CMC Microsystems, Canada. The work was done at Western University Canada, tin accordance with ethics protocol AUP Number: 2014-003 1 ECE, Western University, Canada [email protected] 2 ENSEA/University Cergy-Pontoise/CNRS, France 3 Animal Care and Veterinary Services, Western University, Canada 4 Transonic Scisense Inc., Canada (a) (b) Implant

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats.

Using Bluetooth wireless technology, we developed an implantable telemetry system for measurement of the left ventricular pressure-volume relation in conscious, freely moving rats. The telemetry system consisted of a pressure-conductance catheter (1.8-Fr) connected to a small (14-g) fully implantable signal transmitter. To make the system fully telemetric, calibrations such as blood resistivity...

متن کامل

Implantable RF telemetry for cardiac monitoring in the murine heart: a tutorial review

Research and development of implantable RF telemetry systems intended specifically to enable and support cardiac monitoring of genetically engineered small animal subjects, rats and mice in particular, has already gained significant momentum. This article presents the state of the art review of experimental cardiac monitoring telemetry systems, with strong accent on the systems designed to work...

متن کامل

A current-reuse MICS band CMOS RF transmitter for implantable cardioverter telemetry system

A MICS band CMOS RF transmitter is presented for implantable cardioverter telemtry system. Current-reuse and gain boosting techniques are employed for reducing the current consumption as well as improving the output power. Fabricated in 0.18μm CMOS, the transmitter dissipates 9.3mW from a 1.8-V supply. Measurement shows that the gain boosting capability increases the output power by 1.3–5.5 dB,...

متن کامل

Low-Power, High Data Rate Transceiver System for Implantable Prostheses

Wireless telemetry is crucial for long-term implantable neural recording systems. RF-encoded neurological signals often require high data-rates to transmit information from multiple electrodes with a sufficient sampling frequency and resolution. In this work, we quantify the effects of interferers and tissue attenuation on a wireless link for optimal design of future systems. The wireless link ...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015