Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver.

نویسندگان

  • Joseph C Anderson
  • Wayne J E Lamm
  • Michael P Hlastala
چکیده

Exhaled acetone is measured to estimate exposure or monitor diabetes and congestive heart failure. Interpreting this measurement depends critically on where acetone exchanges in the lung. Health professionals assume exhaled acetone originates from alveolar gas exchange, but experimental data and theoretical predictions suggest that acetone comes predominantly from airway gas exchange. We measured endogenous acetone in the exhaled breath to evaluate acetone exchange in the lung. The acetone concentration in the exhalate of healthy human subjects was measured dynamically with a quadrupole mass spectrometer and was plotted against exhaled volume. Each subject performed a series of breathing maneuvers in which the steady exhaled flow rate was the only variable. Acetone phase III had a positive slope (0.054+/-0.016 liter-1) that was statistically independent of flow rate. Exhaled acetone concentration was normalized by acetone concentration in the alveolar air, as estimated by isothermal rebreathing. Acetone concentration in the rebreathed breath ranged from 0.8 to 2.0 parts per million. Normalized end-exhaled acetone concentration was dependent on flow and was 0.79+/-0.04 and 0.85+/-0.04 for the slow and fast exhalation rates, respectively. A mathematical model of airway and alveolar gas exchange was used to evaluate acetone transport in the lung. By doubling the connective tissue (epithelium+mucosal tissue) thickness, this model predicted accurately (R2=0.94+/-0.05) the experimentally measured expirograms and demonstrated that most acetone exchange occurred in the airways of the lung. Therefore, assays using exhaled acetone measurements need to be reevaluated because they may underestimate blood levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterizing airway and alveolar nitric oxide exchange during tidal breathing using a three-compartment model.

Exhaled nitric oxide (NO) may be a useful marker of lung inflammation, but the concentration is highly dependent on exhalation flow rate due to a significant airway source. Current methods for partitioning pulmonary NO gas exchange into airway and alveolar regions utilize multiple exhalation flow rates or a single-breath maneuver with a preexpiratory breath hold, which is cumbersome for childre...

متن کامل

Breath tests and airway gas exchange.

Measuring soluble gas in the exhaled breath is a non-invasive technique used to estimate levels of respiratory, solvent, and metabolic gases. The interpretation of these measurements is based on the assumption that the measured gases exchange in the alveoli. While the respiratory gases have a low blood-solubility and exchange in the alveoli, high blood-soluble gases exchange in the airways. The...

متن کامل

Airway exchange of highly soluble gases.

Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in th...

متن کامل

Dynamics of soluble gas exchange in the airways. III. Single-exhalation breathing maneuver.

The exchange characteristics of a highly soluble gas with the pulmonary airways during a single-exhalation maneuver were analyzed using a mathematical model previously described by our group (M. E. Tsu et al. Ann. Biomed. Eng. 16: 547-571, 1988). The model integrates the simultaneous exchange of water, heat, and a soluble gas with the pulmonary airways. The purpose of this paper is to provide e...

متن کامل

A single-breath technique with variable flow rate to characterize nitric oxide exchange dynamics in the lungs.

Current techniques to estimate nitric oxide (NO) production and elimination in the lungs are inherently nonspecific or are cumbersome to perform (multiple-breathing maneuvers). We present a new technique capable of estimating key flow-independent parameters characteristic of NO exchange in the lungs: 1) the steady-state alveolar concentration (C(alv,ss)), 2) the maximum flux of NO from the airw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 100 3  شماره 

صفحات  -

تاریخ انتشار 2006