Radiofrequency energy delivery for pulmonary vein isolation: is less more?

نویسندگان

  • Hakan Oral
  • Fred Morady
چکیده

As catheter ablation to eliminate atrial fibrillation (AF) has evolved, new catheter technologies have become available to increase lesion size and improve safety. Pulmonary vein (PV) isolation was first performed with radiofrequency energy using a 4 mm tip electrode. Subsequently, 8–10 mm tip electrodes and irrigated-tip catheters became available. The premise of these systems is that as the catheter tip is cooled either by blood flow or by an irrigant, more energy can be delivered deep in the tissue without reaching the temperature ceiling at the catheter tip–tissue interface. Furthermore, the risk of thrombus or char formation is also reduced. Besides radiofrequency energy, other types of energy such as cryo, microwave, ultrasound, and laser have been used for PV isolation or ablation of atrial myocardium. The power and temperature settings for radiofrequency ablation using a variety of catheters often have been rather empirical. When energy is applied near critical structures such as the PVs or oesophagus, the energy output has been reduced based on anecdotal experience of adverse events. However, there also have been efforts to identify a variety of parameters to titrate the duration and amount of radiofrequency energy application. A fall in impedance of 10 ohm during energy application has been considered to indicate effective lesion development. Other endpoints for energy application have included voltage abatement ( 80%), elimination of PV potentials and/or electrical isolation of the PVs, or achieving conduction block. In one study, a decrease in electrochemical potentials between the distal and proximal electrode pairs was found to be the best predictor of lesion size, particularly during irrigated ablation. Because excessive heating of the tissue–electrode interface may increase the risk of char/thrombus formation and tissue pops, monitoring of microbubble formation under intracardiac echo guidance has also been proposed even in the face of lack of sensitivity. Despite these efforts, a recent animal study pointed out the difficulty in monitoring actual temperatures inside the tissue beyond the electrode– tissue interface. Of particular interest was the substantial mismatch between the temperatures at the electrode– tissue interface and within the myocardium. Furthermore, intramural temperatures continued to rise even after radiofrequency energy application was discontinued. Nilsson et al. report the procedural outcomes of PV isolation by ostial radiofrequency energy ablation using low power for long duration and high power for short duration in patients with paroxysmal and persistent AF. In all patients, an irrigated tip catheter was used and flow rate was limited to 2 mL/min. In the low-power group, radiofrequency energy was applied at a power of 30 W and with a temperature ceiling of 508C for 120 s. In the high-output group, energy was applied at 45 W and 558C for 20 s. Complete PV isolation was achieved in a similar number of patients in both groups; however, more PVs per patient were isolated in the high-output group. The duration of radiofrequency energy application, procedure time, and fluoroscopy time were lower in the high-output group. At a mean follow-up of 15 months, 75% of patients in each group were in sinus rhythm. However, 45% of patients were still being treated with an antiarrhythmic drug in both groups. The authors concluded that 20 s radiofrequency energy applications at a high-power output are preferable to low power, 2 min applications for PV isolation. Although this is the first study that compared radiofrequency energy applications at high and low-power outputs for PV isolation, several prior studies have used high output energy applications for short durations for ostial ablation and circumferential PV ablation. A limitation of this study is that it was not randomized and included a consecutive series of patients. Older patients and more patients with persistent AF were included in the second consecutive group. It appears that as the operators became more comfortable with the ablation technique, they were more liberal in selecting patients, suggesting the presence of a learning effect. A second limitation is that each application was required to be 120 s in the first group, regardless of whether the lesion was effective or not. Therefore, comparisons of the duration of the procedure or radiofrequency energy application may not be meaningful. A third limitation is that the flow rate at the tip of the irrigated catheter was only 2 mL/min. Because of this very low flow rate, it is likely

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial measurement of cerebral microembolic signals during pulmonary vein isolation: a comparison of two ablation techniques.

BACKGROUND Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns have recently been raised that subclinical brain damage may occur because of microembolization during these procedures. We compared the occurrence of bubble formation seen on intracardiac echocardiography and the microembolic signals (MESs) detected by transcranial Doppler on the use of diff...

متن کامل

Randomized comparison of bipolar versus unipolar plus bipolar recordings during segmental ostial ablation of pulmonary veins.

INTRODUCTION Segmental ostial ablation to isolate pulmonary veins is guided by pulmonary vein potentials. The aim of this prospective randomized study was to compare the utility of unipolar plus bipolar electrograms versus only bipolar electrograms as a guide for segmental ablation to isolate the pulmonary veins in patients with atrial fibrillation. METHODS AND RESULTS Isolation of the left s...

متن کامل

Prevalence, characteristics, and predictors of pulmonary vein narrowing after isolation using the pulmonary vein ablation catheter.

BACKGROUND The risk of pulmonary vein narrowing (PVN) after pulmonary vein isolation, using a novel multi-electrode ablation catheter, is unknown. METHODS AND RESULTS Left atrial volume and PV diameters were compared by computed tomography (CT) before and 3 months after pulmonary vein isolation using duty-cycled phased radio frequency energy (2:1 or 4:1 bipolar/unipolar ratio) in 50 patients....

متن کامل

Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation-Paroxysmal Atrial Fibrillation: Is There Any Mystery in Pulmonary Vein Isolation?

In the past decade, catheter ablation of atrial fibrillation (AF) has evolved as one of the most frequently performed procedures in tertiary arrhythmia centers worldwide. With the observation of the actively firing trigger originating from within the pulmonary veins (PVs), ablation strategies have focused at least in paroxysmal AF patients on complete isolation of the PVs. Several different abl...

متن کامل

Bipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report

BACKGROUND Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF ene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2006