Surgical placement of left ventricular lead for cardiac resynchronisation therapy after failure of percutaneous attempt

نویسندگان

  • Mehmet Ezelsoy
  • Suleyman Yazici
  • Ertan Sagbas
  • Muhammed Bayram
  • Nuran Yazicioglu
چکیده

OBJECTIVE Cardiac resynchronisation therapy has been shown to be an effective treatment to improve functional status and prolong survival of patients in advanced chronic heart failure. This study assessed the surgical outcomes of left anterior mini-thoracotomy for the implantation of left ventricular epicardial pacing leads in cardiac resynchronisation therapy. METHODS Our study consisted of 30 consecutive patients who underwent cardiac resynchronisation therapy with a left thoracotomy between November 2010 and April 2012 in our clinic. Postoperative follow up included the assessment of New York Heart Association (NYHA) functional class, electrocardiography and echocardiography. RESULTS There were 22 male and eight female patients with a mean age of 68 ± 5.04 years. All patients were in NYHA class III or IV. Pre-procedure mean left ventricular ejection fraction was 28.1 ± 4.5% and post-procedural ejection fraction improved to 31.7 ± 5.1%. The pre-operative QRS duration changed from 171.7 ± 10.8 to 156.2 ± 4.4 ms after the operation. Also there was a significant reduction in left ventricular end-diastolic dimension from 6.98 ± 0.8 to 6.72 ± 0.8 mm (p < 0 .05), but no change in left ventricular end-systolic dimension and severity of mitral regurgitation. All patients had successful surgical left ventricular lead placement. There was no procedure-related mortality. The mean follow-up time was 40.4 months. CONCLUSION Surgical epicardial left ventricular lead placement procedure is a safe and effective technique in patients with a failed percutaneous attempt.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contralateral transvenous left ventricular lead placement of implantable devices with pre-sternal tunnelling in chronically obstructed subclavian veins

Cardiac resynchronisation therapy (CRT) is a recognised therapy for the management of severe left ventricular dysfunction, advanced congestive cardiac failure (NYHA III or IV), ventricular dyssynchrony (either broad LBBB or mechanical dyssynchrony on echocardiography) and failure of optimal medical therapy to achieve improvement in clinical status. Upgrading right ventricular pacemakers or defi...

متن کامل

CARDIOVASCULAR MEDICINE Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy

Background: Up to 30% of patients with heart failure do not respond to cardiac resynchronisation therapy (CRT). This may reflect placement of the coronary sinus lead in regions of slow conduction despite optimal positioning on current criteria. Objectives: To characterise the effect of CRT on left ventricular activation using non-contact mapping and to examine the electrophysiological factors i...

متن کامل

Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy.

BACKGROUND Up to 30% of patients with heart failure do not respond to cardiac resynchronisation therapy (CRT). This may reflect placement of the coronary sinus lead in regions of slow conduction despite optimal positioning on current criteria. OBJECTIVES To characterise the effect of CRT on left ventricular activation using non-contact mapping and to examine the electrophysiological factors i...

متن کامل

Combined minimally invasive pulmonary vein isolation, left atrial appendage excision and cardiac resynchronization therapy for heart failure: case report.

A 76-year-old male with ischemic cardiomyopathy presented with heart failure symptoms in the absence of angina. Several hospitalizations were required due to heart failure exacerbation and paroxysmal atrial fibrillation. Electrocardiography and tissue synchronization imaging confirmed ventricular dyssynchrony, requiring biventricular pacing. After a failed attempt of percutaneous placement of t...

متن کامل

Combined resynchronisation and implantable defibrillator therapy in left ventricular dysfunction: Bayesian network meta-analysis of randomised controlled trials.

OBJECTIVE To review the evidence base from randomised controlled trials of combined cardiac resynchronisation therapy and implantable cardioverter defibrillator therapy in left ventricular impairment and symptomatic heart failure. DESIGN Bayesian network meta-analysis. DATA SOURCES Medline, Embase, and Cochrane databases up to June 2006. REVIEW METHODS Two reviewers independently assessed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2017