Stationary digital breast tomosynthesis with distributed field emission X-ray tube.

نویسندگان

  • F Sprenger
  • X Calderon
  • E Gidcumb
  • J Lu
  • X Qian
  • D Spronk
  • A Tucker
  • G Yang
  • O Zhou
چکیده

Tomosynthesis requires projection images from different viewing angles. Using a distributed x-ray source this can be achieved without mechanical motion of the source with the potential for faster image acquisition speed. A distributed x-ray tube has been designed and manufactured specifically for breast tomosynthesis. The x-ray tube consists of 31 field emission x-ray sources with an angular range of 30°. The total dose is up to 100mAs with an energy range between 27 and 45 kVp. We discuss the source geometry and results from the characterization of the first prototype. The x-ray tube uses field emission cathodes based on carbon nanotubes (CNT) as electron source. Prior to the manufacturing of the sealed x-ray tube extensive testing on the field emission cathodes has been performed to verify the requirements for commercial tomosynthesis systems in terms of emission current, focal spot size and tube lifetime.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distributed source x-ray tube technology for tomosynthesis imaging.

Tomosynthesis imaging requires projection images from different viewing angles. Conventional systems use a moving xray source to acquire the individual projections. Using a stationary distributed x-ray source with a number of sources that equals the number of required projections, this can be achieved without any mechanical motion. Advantages are a potentially faster image acquisition speed, hi...

متن کامل

Full-field breast tomosynthesis.

Breast tomosynthesis is a 3-dimensional (3-D) imaging technology that involves acquiring images of a stationary compressed breast at multiple angles during a short scan. The individual images are then reconstructed into a series of thin high-resolution slices that displayed individually or in a dynamic ciné mode. Tomosynthesis can reduce or eliminate the tissue overlap effect. While holding the...

متن کامل

Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays

Stationary digital breast tomosynthesis (sDBT) with distributed X-ray sources based on carbon nanotube (CNT) field emission cathodes has been recently proposed as an approach that can prevent motion blur produced by traditional DBT systems. In this paper, we simulate a geometric calibration method based on a proposed multi-source CNT X-ray sDBT system. This method is a projection matrix-based a...

متن کامل

Breast tomosynthesis imaging configuration optimization based on computer simulation

Digital tomosynthesis is an innovative imaging technology for early breast cancer detection by providing three-dimensional anatomical information with fast image acquisition and low-dose radiation. Most of current breast tomosynthesis systems utilize a design where a single x-ray tube moves along an arc above objects over a certain angular range. The mechanical movement and patient motion durin...

متن کامل

Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications.

Digital breast tomosynthesis is a three-dimensional imaging technique that provides an arbitrary set of reconstruction planes in the breast from a limited-angle series of projection images acquired while the x-ray tube moves. Traditional shift-and-add (SAA) tomosynthesis reconstruction is a common mathematical method to line up each projection image based on its shifting amount to generate reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of SPIE--the International Society for Optical Engineering

دوره 7961  شماره 

صفحات  -

تاریخ انتشار 2011