Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method

نویسندگان

  • Lorena Bouzas
  • Jesús Hermida
  • J Carlos Tutor
چکیده

BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA) commercialized for everolimus quantification. METHODS Sirolimus concentrations were determined in whole-blood samples from liver and kidney transplant recipients using the Innofluor Certican FPIA (Seradyn Inc.) run on a TDx analyser (Abbott Laboratories), Sirolimus MEIA run on an IMx analyser (Abbott Laboratories), and HPLC (UV detection) methods. RESULTS The Innofluor FPIA has a similar cross-reactivity with everolimus and sirolimus, and the within- and between-run coefficients of variation obtained for sirolimus determination were 2.7%-13.3%. In analysing different blood samples from liver and kidney transplant patients the linear regressions obtained were: FPIA = 1.12 HPLC + 0.43 (n=104, r=0.874), MEIA = 1.14 HPLC (n=146, r=0.892), and FPIA = 1.00 MEIA + 0.29 (n=106, r=0.941). Better correlation coefficients were obtained between the methods in the liver transplant samples (r>or=0.900) than in the kidney transplant samples (r>or=0.849). No significant effect was found for sirolimus clearance or the blood hematocrit on the relationship between the results produced by both immunoassays and HPLC. CONCLUSION The Innofluor FPIA is a valid alternative with an analogous performance to the MEIA for the therapeutic monitoring of sirolimus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of cyclosporine by liquid chromatography and three immunoassays in blood from liver, cardiac, and renal transplant recipients.

In an effort to replace HPLC for whole-blood determination of cyclosporine (CsA), we compared HPLC with radioimmunoassay (RIA; INCSTAR, Cyclo-Trac SP assay), fluorescence polarization immunoassay (FPIA; Abbott TDx), and in-house modified enzyme-multiplied immunoassay technique (EMIT; Syva Co.). For blood samples from 200 various transplant recipients, RIA = 1.262 (HPLC) - 8.16, r = 0.983; FPIA ...

متن کامل

Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients.

We evaluated the MEIA II with blood samples with added tacrolimus (3.0, 5.0, 11.0, and 22.0 microg/L). The assay had acceptable recoveries (99-103%) and intraday imprecision (<16.0%) across the range of concentrations studied, except for the recoveries at 3.0 microg/L (86.3%) and 5.0 microg/L (80.7%). Comparison of liver (n = 116) and renal (n = 113) patient samples measured by MEIA II against ...

متن کامل

HPLC-microparticle enzyme immunoassay specific for tacrolimus in whole blood of hepatic and renal transplant patients.

Tacrolimus is a relatively new immunosuppressant used in organ transplantation to prevent graft rejection. However, its use is not devoid of side effects, making it important to maintain blood concentrations within therapeutic ranges. Several analytical methods are currently available for routine drug monitoring. However, these methods are based on use of the same monoclonal antibody, which als...

متن کامل

Comparison of cyclosporin G (Nva2-cyclosporin) concentrations measured in whole blood by monoclonal fluorescence polarization immunoassay, monoclonal radioimmunoassay, and HPLC.

Two commercial monoclonal immunoassays for monitoring cyclosporin A were used to measure whole-blood concentrations of the immunosuppressant cyclosporin G (CsG) in renal transplant patients. We performed a three-way comparison of these two immunoassays and HPLC. Although the two immunoassays agreed favorably, both the monoclonal fluorescence polarization immunoassay and the monoclonal RIA yield...

متن کامل

Comparison of ELISA method versus MEIA method for daily practice in the therapeutic monitoring of tacrolimus.

BACKGROUND For the adequate management of transplant patients on tacrolimus therapy, it is important to obtain optimal blood concentrations. The purpose of this study was to determine the most appropriate method for daily practice of tacrolimus determination in whole blood. We compared enzyme-linked immunosorbent assay (ELISA) with microparticle enzyme immunoassay (MEIA), using European control...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 114  شماره 

صفحات  -

تاریخ انتشار 2009