Parametric vs. non-parametric statistics of low resolution electromagnetic tomography (LORETA).

نویسندگان

  • R W Thatcher
  • D North
  • C Biver
چکیده

This study compared the relative statistical sensitivity of non-parametric and parametric statistics of 3-dimensional current sources as estimated by the EEG inverse solution Low Resolution Electromagnetic Tomography (LORETA). One would expect approximately 5% false positives (classification of a normal as abnormal) at the P < .025 level of probability (two tailed test) and approximately 1% false positives at the P < .005 level. EEG digital samples (2 second intervals sampled 128 Hz, 1 to 2 minutes eyes closed) from 43 normal adult subjects were imported into the Key Institute's LORETA program. We then used the Key Institute's cross-spectrum and the Key Institute's LORETA output files (*.lor) as the 2,394 gray matter pixel representation of 3-dimensional currents at different frequencies. The mean and standard deviation *.lor files were computed for each of the 2,394 gray matter pixels for each of the 43 subjects. Tests of Gaussianity and different transforms were computed in order to best approximate a normal distribution for each frequency and gray matter pixel. The relative sensitivity of parametric vs. non-parametric statistics were compared using a "leave-one-out" cross validation method in which individual normal subjects were withdrawn and then statistically classified as being either normal or abnormal based on the remaining subjects. Log10 transforms approximated Gaussian distribution in the range of 95% to 99% accuracy. Parametric Z score tests at P < .05 cross-validation demonstrated an average misclassification rate of approximately 4.25%, and range over the 2,394 gray matter pixels was 27.66% to 0.11%. At P < .01 parametric Z score cross-validation false positives were 0.26% and ranged from 6.65% to 0% false positives. The non-parametric Key Institute's t-max statistic at P < .05 had an average misclassification error rate of 7.64% and ranged from 43.37% to 0.04% false positives. The nonparametric t-max at P < .01 had an average misclassification rate of 6.67% and ranged from 41.34% to 0% false positives of the 2,394 gray matter pixels for any cross-validated normal subject. In conclusion, adequate approximation to Gaussian distribution and high cross-validation can be achieved by the Key Institute's LORETA programs by using a log10 transform and parametric statistics, and parametric normative comparisons had lower false positive rates than the non-parametric tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional imaging with low-resolution brain electromagnetic tomography (LORETA): a review.

This paper reviews several recent publications that have successfully used the functional brain imaging method known as LORETA. Emphasis is placed on the electrophysiological and neuroanatomical basis of the method, on the localization properties of the method, and on the validation of the method in real experimental human data. Papers that criticize LORETA are briefly discussed. LORETA publica...

متن کامل

Recursive penalized least squares solution for dynamical inverse problems of EEG generation.

In the dynamical inverse problem of electroencephalogram (EEG) generation where a specific dynamics for the electrical current distribution is assumed, we can impose general spatiotemporal constraints onto the solution by casting the problem into a state space representation and assuming a specific class of parametric models for the dynamics. The Akaike Bayesian Information Criterion (ABIC), wh...

متن کامل

Localization of Simultaneous Multiple Sources using SMS-LORETA

In this paper we present a new localization method SMS-LORETA (Simultaneous Multiple SourcesLow Resolution Brain Electromagnetic Tomography), capable to locate efficiently multiple simultaneous sources. The new method overcomes some of the drawbacks of sLORETA (standardized Low Resolution Brain Electromagnetic Tomography). The key idea of the new method is the iterative search for current dipol...

متن کامل

Evaluation and validity of a LORETA normative EEG database.

To evaluate the reliability and validity of a Z-score normative EEG database for Low Resolution Electromagnetic Tomography (LORETA), EEG digital samples (2 second intervals sampled 128 Hz, 1 to 2 minutes eyes closed) were acquired from 106 normal subjects, and the cross-spectrum was computed and multiplied by the Key Institute's LORETA 2,394 gray matter pixel T Matrix. After a log10 transform o...

متن کامل

Assessment of Stress Cognitive Control and Executive Function with Stress Control Rating Scale (ECOSTRESS) and Low Resolution Brain Electromagnetic Tomography (LORETA) (In Portuguese People in Situations of Unemployment and Economic Insufficiency)

This article reviews the constructs of stress, appraisal, coping, according to a transactional perspective, and executive function, and presents a stress control rating scale (ECOSTRESS), which design is founded in these constructs. This psychometric tool is useful in the assessment of cognitive control of stress, correlated with the function of dorsolateral prefrontal cortex. It has been valid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical EEG and neuroscience

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2005