Flow dynamics of QW7437, a new dodecafluoropentane ultrasound contrast agent, in the microcirculation: microvascular mechanisms for persistent tissue echo enhancement.

نویسندگان

  • T Yasu
  • G W Schmid-Schönbein
  • B Cotter
  • A N DeMaria
چکیده

OBJECTIVES The purpose of this study was to test the hypothesis that a subgroup of QW7437 microbubbles, dodecafluoropentane-based ultrasound contrast microspheres, resides for prolonged periods in the microvasculature. BACKGROUND QW7437 produces echo enhancement in myocardium which may persist relatively longer than opacification in the left ventricular cavity. The mechanism for this persistent enhancement remains unknown. METHODS The transit of fluorescently labeled erythrocytes was examined by fluorescence intravital microscopy in the microvessels in five rat mesenteries. Ten rats were used to observe the behavior of fluorescently labeled QW7437 microbubbles in the mesenteric microcirculation. RESULTS There was no significant change in erythrocyte velocity in the arterioles and venules after the administration of QW7437 microbubbles (0.05 ml/kg) preactivated by negative hydrodynamic pressure. Of 552 microbubbles observed in four arterioles and five capillaries, 549 (99.5%) passed without stoppage (> or = 0.1 s stoppage); only one stopped transiently in arteriole and two in capillaries, each for <0.5 s. Sixty-five of 478 microbubbles (13.6%) observed in six postcapillary venules 11 to 30 microm in diameter and 24 of 408 microbubbles (5.9%) in four venules 31 to 50 microm in diameter stopped transiently (0.1 to 180 s) with an attachment to venular endothelium; the remaining microbubbles passed through the venules without stoppage. CONCLUSIONS Prolonged survival as microbubbles in the circulation and transient stoppage of a subgroup of microbubbles in the microvasculature, particularly in venules, are potential mechanisms for the persistent tissue echo enhancement by QW7437 microbubbles during contrast echocardiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast harmonic ultrasound and indocyanine-green fluorescence video angiography for evaluation of dermal and subdermal microcirculation in free parascapular flaps.

PURPOSE Contrast harmonic ultrasound (CHI) with a linear transducer is a new diagnostic approach that allows dynamic and quantitative flow detection of tissue perfusion in microsurgery. The aim of the study was the evaluation of perfusion of the dermal and subdermal layers of microvascular tissue transplants with CHI in comparison to ICG-fluorescence angiography. MATERIAL AND METHOD In a pros...

متن کامل

Myocardial contrast echocardiography: advantages of quantitative analysis.

Every technology yet to be consolidated needs to be compared with reference methods to evaluate its accuracy. Over the past years, contrast echocardiography has been compared against a variety of standards. In experimental studies, myocardial perfusion data from ultrasound have been compared with the measurements of coronary blood flow obtained by labeled microspheres, or with infarct size foll...

متن کامل

Quantification methods in contrast echocardiography.

New technologies and the availability of new echo-contrast agents have resulted in advances of diagnostic and prognostic indications of left ventricular opacification (LVO) and myocardial perfusion. The clinical diagnostic value of ultrasound contrast media for LVO and its impact on the clinical decision-making process has been demonstrated in several studies. Recent research aims at developing...

متن کامل

Perfusion and vascular permeability: basic concepts and measurement in DCE-CT and DCE-MRI.

The microvascular network formed by the capillaries supplies the tissues and permits their function. It provides a considerable surface area for exchanges between blood and tissues. All pathological conditions cause changes in the microcirculation. These changes can be used as imaging biomarkers for the diagnosis of lesions and optimisation of treatment. Among the many imaging techniques develo...

متن کامل

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 1999