Improving fluid balance monitoring on the wards
نویسندگان
چکیده
Clinical experience and nursing metrics have consistently identified poor documentation of fluid balance monitoring at Milton Keynes University Hospital, compromising patient safety and quality of care. This project aimed to increase the percentage of fluid balance charts correctly completed on the wards. Three areas for improvement were identified: understanding the importance of good fluid balance monitoring, correct identification of patients requiring monitoring, and ease of completion of fluid balance charts. Three interventions were deployed on two acute medical awards in consecutive cycles; 1) small group education for staff, 2) creation of board magnets to aid the multidisciplinary team to identify patients requiring monitoring, 3) modification of the current fluid balance chart. Questionnaires were utilised to highlight improvements with current charts and measured staff awareness pre and post education. Each intervention was implemented for one week followed by daily surveys for four days to monitor compliance. Initial results showed a range of 6-12 charts used daily per ward. Of these 0-45% of them were correctly filled. Post education there was a reduced number of inappropriate charts. Introduction of board magnets improved correlation between doctors and nurses in identification of patients (52% before, 77% after magnets). Following modification there was a subjective improvement in the quality of chart completion. This study highlighted that understanding and use of fluid balance monitoring can be improved for nurses, health care assistants (HCAs), and doctors. These improvements allow better documentation and safer patient care. As a result, Milton Keynes University Hospital is investing in magnets and modified charts for a Trust-wide pilot.
منابع مشابه
Morbidity and mortality of neonates admitted in general paediatric wards at Kenyatta National Hospital.
BACKGROUND Neonatal morbidity and mortality is high in developing countries. Facilities for specific neonatal care are limited in Kenya with no neonatal intensive care unit in the public health institutions. The new born unit at Kenyatta National Hospital (KNH) cannot accommodate all neonates so a number of these are admitted to the general paediatric wards. OBJECTIVES To establish the morbid...
متن کاملAssociation between chloride-rich versus chloride-restrictive intravenous fluid administration and acute kidney injury in cardiovascular patients in ICU wards
The aim of the study was to investigate the therapeutic effect of chloride-restrictive fluid to prevent acute kidney injury (AKI) in cardiovascular patients in intensive care unit (ICU) wards. Between January 2013 and September 2014, 456 patients admitted to ICU wards following diagnosis of cardiovascular disease were recruited and randomized to receive chloride-rich (232 patients) or chloride-...
متن کاملImprovement of fluid balance monitoring through education and rationalisation
Fluid input/output charts in hospital inpatients are a valuable source of information for doctors reviewing intravenous fluid prescription, but are notorious for being incomplete and inaccurate. Lack of awareness of the importance of fluid balance amongst nursing staff and an excess of unnecessary monitoring are two factors contributing to the problem. We conducted a quality improvement project...
متن کاملThe Effect of 8 weeks of Core stability with improving Knee Proprioception Training on Balance, Pain and Functional Disability in Women with Chronic Knee Pain
Considering the prevalence of pain and disability in the knee joint, the present study investigated the effect of core stability training with improving knee joint proprioception on balance, pain and functional disability of women with chronic knee pain. 20 women aged 30 to 50 with chronic knee pain were placed in two experimental and control groups. To measure static and dynamic balance, pain ...
متن کاملPulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study
INTRODUCTION The choice of invasive systemic haemodynamic monitoring in critically ill patients remains controversial as no multicentre comparative clinical data exist. Accordingly, we sought to study and compare the features and outcomes of patients who receive haemodynamic monitoring with either the pulmonary artery catheter (PAC) or pulse contour cardiac output (PiCCO) technology. METHODS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2015