Objective perimetry using the multifocal visual evoked potential in central visual pathway lesions.

نویسندگان

  • A I Klistorner
  • S L Graham
  • J Grigg
  • C Balachandran
چکیده

AIMS To examine the ability of the multifocal pattern visual evoked potential (mVEP) to detect field loss in neurological lesions affecting the visual pathway from the chiasm to the cortex. METHOD The mVEPs recorded in the clinic were retrospectively reviewed for any cases involving central neurological lesions. Recordings had been performed with the AccuMap V1.3 objective perimeter, which used an array of four bipolar occipital electrodes to provide four differently oriented channels for simultaneous recording. 19 patients with hemianopias were identified. Of these there were 10 homonymous hemianopias with hemifield type loss, two bitemporal hemianopias, and seven homonymous hemianopias with quadrantanopic distribution. A comparison with subjective field results and CT/MRI findings was done to determine the relation between the two methods of visual field mapping and any relation with the anatomical location of the lesion and the mVEP results. RESULTS In all hemianopic type cases (12) the defect was demonstrated on the mVEP and showed good correspondence in location of the scotoma (nine homonymous and two bitemporal). The topographic distribution was similar but not identical to subjective testing. Of the seven quadrantanopic type hemianopias, only four were found to have corresponding mVEP losses in the same areas. In the three cases where the mVEP was normal, the type of quadrantanopia had features consistent with an extra-striate lesion being very congruous, complete, and respecting the horizontal meridian. CONCLUSIONS The mVEP can detect field loss from cortical lesions, but not in some cases of homonymous quadrantanopia, where the lesion may have been in the extra-striate cortex. This supports the concept that the mVEP is generated in V1 striate cortex and that it may be able to distinguish striate from extra-striate lesions. It implies caution should be used when interpreting "functional" loss using the mVEP if the visual field pattern is quadrantic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abnormalitites of Visual Evoked Potential in Migraine Patients

Background: Visual evoked potential (VEP) is regarded as a useful, reliable and non-invasive technique for the diagnosis of lesions in the optic pathway.  This technique was used to investigate visual function in migraine.   Materials and Methods: 53 migraine patients (27 migraine cases with aura and 26 common migraine cases) and 55 controls were prospectively enrolled in this study.  Visual ev...

متن کامل

Objective perimetry using a four-channel multifocal VEP system: correlation with conventional perimetry and thickness of the retinal nerve fibre layer.

PURPOSE There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. METHOD Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern...

متن کامل

Comparing multifocal pupillographic objective perimetry (mfPOP) and multifocal visual evoked potentials (mfVEP) in retinal diseases

Multifocal pupillographic objective perimetry (mfPOP) shows regions of slight hypersensitivity away from retinal regions damaged by diabetes or age-related macular degeneration (AMD). This study examines if such results also appear in multifocal visual evoked potentials (mfVEPs) recorded on the same day in the same patients. The pupil control system receives input from the extra-striate cortex,...

متن کامل

Multifocal Visual Evoked Potential in Eyes With Temporal Hemianopia From Chiasmal Compression: Correlation With Standard Automated Perimetry and OCT Findings.

Purpose To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Methods T...

متن کامل

SCIENTIFIC REPORT Multifocal VEP in children: its maturation and clinical application

Aim: To study the maturation of multifocal visual evoked potentials (multifocal VEP) in normal children between the ages of 5 and 16 years and to apply the results clinically in selected cases to the diagnosis of optic pathway diseases. Method: 70 normal children were recruited from the community and multifocal VEP (Accumap ObjectiVision, Sydney, Australia) was recorded. The waveform of the evo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 89 6  شماره 

صفحات  -

تاریخ انتشار 2005