Rapid and simple determination of phthalates in plastic toys by a thermal desorption-GC/MS method.

نویسندگان

  • Tetsuro Yuzawa
  • Chuichi Watanabe
  • Robert R Freeman
  • Shin Tsuge
چکیده

A thermal desorption (TD)-GC/MS method was applied for the determination of phthalates in plastic children's toys. The method, which does not need any cumbersome sample pretreatment such as solvent extraction, filtration and derivatization, has been proved to be useful not only as a sensitive analytical method to evaluate phthalate concentration in the toys, but also as a rapid and practical screening method to check whether the concentration exceeds the regulatory limit.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DESI MS based screening method for phthalates in consumer goods.

Phthalates are used as plasticizes in many everyday items, but some of them are known as hormone disruptors, being especially harmful during childhood. The European Union therefore restricted their application in children's toys and certain food packaging to 0.1%w. Due to the ever increasing number of plastic-containing consumer goods, rapid screening methods are needed to ensure and improve co...

متن کامل

HCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction

In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...

متن کامل

Comparative study of thermal desorption and solvent extraction-gas chromatography-mass spectrometric analysis for the quantification of phthalates in polymers.

For the quantitative analysis of phthalates in polymers, a thermal desorption (TD)-GC-MS method was compared with solvent extraction (SE)-GC-MS methods which require the long pretreatment procedures using large amount of harmful organic solvents. Calibration curves of TD-GC-MS showed good linearity (r(2)>0.9997) and low method detection limit (<30mg/kg with 9.0% RSD). Quantification results for...

متن کامل

Determination of residual solvents in pharmaceuticals by thermal desorption-GC/MS.

A novel method for the determination of residual solvents in pharmaceuticals by thermal desorption (TD)-GC/MS has been established. A programmed temperature pyrolyzer (double shot pyrolyzer) is applied for the TD. This method does not require any sample pretreatment and allows very small amounts of the sample. Directly desorbed solvents from intact pharmaceuticals (ca. 1 mg) in the desorption c...

متن کامل

Rapid determination of decabromodiphenyl ether in polystyrene by thermal desorption-GC/MS.

A rapid determination of decabromodiphenyl ether (DeBDE) in polystyrene (PS) by thermal desorption (TD)-GC/MS was studied. The TD-GC/MS method using a pyrolysis-GC/MS system allowed the quick quantification of DeBDE in a waste TV back plate composing of a PS flame-retarded with polybrominated diphenyl ethers on the basis of the resulting chromatogram with a ca. 4% relative standard deviation wi...