The Elimination of Body Resonance Distortion from the Direct - Body

نویسندگان

  • JOHN N. EDSON
  • GERALD H. FLAMM
چکیده

T HE recorded ballistocardiogram is a distorted representation of cardiovascular forces.1, 2, 3 These forces, which are generated by the contracting heart and accelerated blood, are transformed in transmission to the surface of the body. The resultant body movement is determined by the amplitudes of the transmitted forces and the mechanical response of the body. It is the purpose of this paper to present a practical means of neutralizing the distorting effect of the body's resonance on the longitudinal ballistocardiogram of the supine subject lying on a rigid surface. The longitudinal motion of the supine body may be described mathematically, if it is assumed that the body behaves as a simple mechanical system. The normalized displacement and velocity amplitude responses of such a simplified body to sinusoidal forces are given in equations (1) and (2):4' 5, 6, 7

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of 12 Weeks of Systematic and Functional Corrective Exercises on Body Posture of Students Suffering From Pronation Distortion Syndrome

Objectives: Pronation distortion syndrome is one of the common physical deformities, that causes distortions in the skeletal structures of the feet. The current study aimed to determine the effects of 12 weeks of systematic and functional corrective exercises on the body posture of students with pronation distortion syndrome.  Methods: In this quasi-experimental study, 30 volunteers suffering ...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Output-Conductance Transition-Free Method for Improving Radio-Frequency Linearity of SOI MOSFET Circuits

In this article, a novel concept is introduced to improve the radio frequency (RF) linearity of partially-depleted (PD) silicon-on-insulator (SOI) MOSFET circuits. The transition due to the non-zero body resistance (RBody) in output conductance of PD SOI devices leads to linearity degradation. A relation for RBody is defined to eliminate the transition and a method to obtain transition-free c...

متن کامل

A Method for Body Fat Composition Analysis in Abdominal Magnetic Resonance Images Via Self-Organizing Map Neural Network

Introduction: The present study aimed to suggest an unsupervised method for the segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in axial magnetic resonance (MR) images of the abdomen. Materials and Methods: A self-organizing map (SOM) neural network was designed to segment the adipose tissue from other tissues in the MR images. The segmentation of SAT and VA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005