Miniaturized Phased-Array Ultrasonic Endoscope Initial Experience With Intracardiac Imaging in Piglets

نویسندگان

  • Lilliam M. Valdes-Cruz
  • Eleftherios Sideris
چکیده

Background. Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array devices introduced directly into the right atrium in open-chested animals. The purpose of this study was to assess the feasibility of using a custom-made, very small phased-array endoscope for intracardiac imaging introduced intravascularly through a jugular venous approach in young piglets. Methods and Results. Experimental atrial septal defects created in four piglets (3-4 weeks old) had been closed with a buttoned atrial septal defect closure device consisting of an occluder in the left atrium and a counteroccluder in the right atrium. Five to 15 days after atrial septal defect closure, the piglets were returned to the experimental laboratory, where a 6.3-mm, 17-element, 5-MHz phased-array probe mounted on a 4-mm endoscope was introduced through a cutdown incision of the external jugular vein and advanced to the right atrium. From the right atrium all four cardiac chambers, their inflows and outflows, and all four valves were well imaged with minimal superior and inferior rotation. High-resolution imaging of the atrial septum defined with anatomical accuracy, later verified by autopsy, the exact placement of both the occluder and counteroccluder in the left and right sides of the atrial septal defects and the absence of any shunting across the atrial septum in any of the four animals. Conclusions. Our efforts indicate that transvascular passage of small phased-array probes can be easily accomplished and is a promising technique for detailed visualization of cardiac structures. This approach may provide an alternative to transesophageal echocardiography, particularly for guiding interventional procedures such as placement of transcatheter closure devices in pediatric patients. (Circulation 1991;83:1023-1027)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvascular intracardiac applications of a miniaturized phased-array ultrasonic endoscope. Initial experience with intracardiac imaging in piglets.

BACKGROUND Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array device...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Design, implementation, and comparison of guided wave phased arrays using embedded piezoelectric wafer active sensors for structural health monitoring

Phased array can interrogate large structural areas from a single location using ultrasonic guided waves generated by tuned piezoelectric wafer active sensors that are permanently attached (embedded) to the structure. Various array parameters determine the array beamforming and steering characteristics. This paper aims to bring up several one or two dimension array designs and research on their...

متن کامل

The Ultrasonic Phased Array Inspection Technology Used in Tubular Joint Welds of Offshore Platform Structures

Aimed at the practical requirement of tubular joint welds inspection of offshore platform structures, the ultrasonic phased array inspection algorithm for offshore platform structures is proposed in this paper, and the ultrasonic phased array inspection system for offshore platform structures is developed. The experiment of tubular joint model is performed with the ultrasonic phased array inspe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005