Formation of Abnormal Fistula on Arteriovenous Fistula in a Patient with Buttonhole Cannulation: A Case Report

نویسندگان

  • Wen Cao
  • Lin Chen
  • Mei Shi
  • Li Zhou
  • Ping Fu
چکیده

Buttonhole cannulation has been suggested as a technique that may lead to a reduction in many complications when compared with other techniques such as rope-ladder cannulation. Despite all above, some complications still continue, which may lead to a dysfunction of the arteriovenous fistula (AVF) and inadequate dialysis, having an impact on the quality of life of the patients or eventually making the vascular access unusable. We report a 47-year-old Chinese male with end-stage renal disease who had maintenance hemodialysis three times a week for 5 years. The AVF on the left wrist was operated 5 years ago and proved to be functionally effective with some monitoring and surveillance measures in the fourth year of hemodialysis. Two months later, the buttonhole cannulation technique was applied due to fistula punctuation difficulty by previous aneurysmal dilatation. After 10 times of buttonhole cannulation, the edema on the left forearm of the patient indicated a dysfunction of the AVF. This was further confirmed by the HD02 hemodialysis monitor and a vascular ultrasound, revealing a recirculation of 87%, an abnormal fistula between the AVF and the vein together with thrombus, and aneurysmal dilatation near the anastomosis. The site of cannulation was changed to avoid heavy recirculation (reduced to 25%), and a new AVF on the left wrist was successfully operated. Abnormal fistula on the AVF and vein during buttonhole cannulation is rarely reported, which reminds us that vascular access surveillance should be done regularly before and during the process of construction to find a possible dysfunction of the AVF in patients undergoing buttonhole cannulation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.

BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, a...

متن کامل

Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.

BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...

متن کامل

Spinal dural arteriovenous fistula : a case report

Background: Spinal dural AVF is the most common type of spinal vascular malformation. However, presenting symptoms differ according to site of spinal involvement. This study described a case of arteriovenous malformation with paraparesis and incontinence. Case Presentation: Diagnosis of patient was confirmed by clinical and imaging examination using magnetic resonance image and ruling out ot...

متن کامل

Comparing the Effect of Cryotherapy and Acupressure on Pain Intensity of Arteriovenous Fistula Cannulation in Patients Hemodialysis

Introduction: Patients with kidney failure undergoing hemodialysis are frequently exposed to the hemodialysis needles are inserted into the arteriovenous fistulas; one of the important interventions in nursing care is use of nonpharmacological interventions for relief pain. Therefore, this study was conducted to compare the effect of cryotherapy and acupressure on the pain intensity of needle ...

متن کامل

Cannulation technique influences arteriovenous fistula and graft survival

Hemodialysis patient survival is dependent on the availability of a reliable vascular access. In clinical practice, procedures for vascular access cannulation vary from clinic to clinic. We investigated the impact of cannulation technique on arteriovenous fistula and graft survival. Based on an April 2009 cross-sectional survey of vascular access cannulation practices in 171 dialysis units, a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015