BOLD Noise Assumptions in fMRI
نویسندگان
چکیده
This paper discusses the assumption of Gaussian noise in the blood-oxygenation-dependent (BOLD) contrast for functional MRI (fMRI). In principle, magnitudes in MRI images follow a Rice distribution. We start by reviewing differences between Rician and Gaussian noise. An analytic expression is derived for the null (resting-state) distribution of the difference between two Rician distributed images. This distribution is shown to be symmetric, and an exact expression for its standard deviation is derived. This distribution can be well approximated by a Gaussian, with very high precision for high SNR, and high precision for lower SNR. Tests on simulated and real MR images show that subtracting the time-series mean in fMRI yields asymmetrically distributed temporal noise. Subtracting a resting-state time series from the first results in symmetric and nearly Gaussian noise. This has important consequences for fMRI analyses using standard statistical tests.
منابع مشابه
Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملEffect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field
Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...
متن کاملEffect of Physiological Noise on Thoraco-lumbar Spinal Cord FMRI in 3T Magnetic Field
Introduction: Functional MRI methods have been used to study sensorimotor processing in the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from the physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as significant sources of noise, especi...
متن کاملTemporal sensitivity of event-related fMRI.
The temporal resolution of event-related fMRI is limited by the low sampling rate of typical MR whole brain protocols and by the slow rate of the BOLD response. Within the assumptions of the General Linear Model, we explore the tolerance of regression analyses of fMRI data to errors in the timing of the model relative to the experimental data under a number of circumstances. Given the sensitivi...
متن کاملEvaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies
Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International Journal of Biomedical Imaging
دوره 2006 شماره
صفحات -
تاریخ انتشار 2006