Systematic comparison between line integrated densities measured with interferometry and polarimetry at JET.
نویسندگان
چکیده
A systematic comparison between the line integrated electron density derived from interferometry and polarimetry at JET has been carried out. For the first time the reliability of the measurements of the Cotton-Mouton effect has been analyzed for a wide range of main plasma parameters and the possibility to evaluate the electron density directly from polarimetric data has been studied. The purpose of this work is to recover the interferometric data with the density derived from the measured Cotton-Mouton effect, when the fringe jump phenomena occur. The results show that the difference between the line integrated electron density from interferometry and polarimetry is with one fringe (1.143 x 10(19) m(-2)) for more than 90% of the cases. It is possible to consider polarimetry as a satisfactory alternative method to interferometry to measure the electron density and it could be used to recover interferometric signal when a fringe jumps occurs, preventing difficulties for the real-time control of many experiments at the JET machine.
منابع مشابه
Are There Rotation Measure Gradients across Active Galactic Nuclei Jets?
We report on multi-frequency polarimetry very long baseline interferometry observations of active galactic nuclei using the Very Long Baseline Array. These observations are used to construct images of the Faraday rotation measure (RM) in J1613+342, Mrk 501, 3C 371, and BL Lac. Despite having resolved the jets in total intensity and polarization for three of these sources no RM gradients are fou...
متن کاملPolarimetric Interferomtry
SAR polarimetry makes use of the polarization dependent scattering response of each pixel within the imaged area. The polarimetric response is highly sensitive to the scattering mechanism of a pixel. SAR interferometry is sensitive to the location of a pixel and its scattering geometry. The location of a pixel can be measured by the phase difference between two coherent SAR images using SAR int...
متن کاملMultifrequency Polarimetry of the Nrao 140 Jet: Possible Detection of a Helical Magnetic Field and Constraints on Its Pitch Angle
We present results from multifrequency polarimetry of NRAO 140 using the Very Long Baseline Array. These observations allow us to reveal the distributions of both the polarization position angle and the Faraday rotation measure (RM). These distributions are powerful tools to discern the projected and line-of-sight components of the magnetic field, respectively. We find a systematic gradient in ...
متن کاملPolarimetric Interferometry and Differential Interferometry
This Lecture mainly based on [1, 2] presents the role of Polarimetry in SAR Interferometry. A general formulation for vector wave interferometry is presented that includes conventional scalar interferometry presented in the respective former lecture as a special case. Based on this formulation, the coherence optimization problem can be solved to obtain the optimum scattering mechanisms that lea...
متن کاملVery Long Baseline Array observations of the Intraday Variable source J 1128 + 592
Context. Short time-scale flux density variations of flat spectrum radio sources are often explained by the scattering of radio waves in the turbulent ionized Interstellar Matter of the Milky Way. One of the most convincing observational arguments in favor of this is the annual modulation of the variability time-scale caused by the Earth orbital motion around the Sun. J1128+5925 is a recently d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 80 6 شماره
صفحات -
تاریخ انتشار 2009