Description and evaluation of a delivery system for aerosolized prostacyclin.

نویسندگان

  • Mark S Siobal
  • Richard H Kallet
  • Jean-François Pittet
  • Edna L Warnecke
  • Roger W Kraemer
  • Rajeev V Venkayya
  • Julin F Tang
چکیده

INTRODUCTION Inhaled vasodilators such as nitric oxide and aerosolized prostacyclin (PGI(2)) are used to treat severe hypoxemia in acute respiratory distress syndrome. Preferential distribution of nitric oxide and PGI(2) to ventilated areas of the lung causes selective pulmonary vasodilation, improved ventilation/perfusion matching, and decreased hypoxemia. Because of the technical limitations of previously described methods, we developed a PGI(2) delivery technique that allows the aerosolized drug dose to be easily calculated, set, and adjusted. METHODS A 50 mL solution of PGI(2) (3.0x10(4) ng/mL) and a 500 mL normal saline solution were infused by a dual-channel volumetric infusion pump into a MiniHEART jet nebulizer that has a manufacturer-specified output of 8 mL/h at a set flow of 2 L/min. By adjusting the pump infusion rate to achieve a total output of 8 mL/h, the PGI(2) concentration was altered to deliver a calculated aerosolized dose of 10-50 ng/kg/min. The effectiveness of the delivery system was retrospectively evaluated by way of the responses of 11 severely hypoxemic acute respiratory distress syndrome patients who received PGI(2) via the system we describe. The MiniHEART nebulizer output, particle size, and dose delivery were evaluated in a laboratory bench study, using a set flow of 2 L/min. RESULTS Aerosolized PGI(2) therapy (mean dose 28 +/- 17 ng/kg/min, range 10-50 ng/kg/min) significantly increased the ratio of P(aO)(2) to fraction of inspired oxygen (P(aO)(2)/F(IO)(2)) (60 +/- 11 mm Hg vs 80 +/- 17 mm Hg, p = 0.003) and arterial oxygen saturation measured via pulse oximetry (86 +/- 8% vs 94 +/- 3%, p = 0.005) (differences evaluated with the Wilcoxon signed rank test). There was no difference in positive end-expiratory pressure, mean airway pressure, or F(IO)(2), before and after aerosolized PGI(2) (p > 0.05). Nebulizer output was 6.8 +/- 0.9 mL/h, range 6.0-7.8 mL/h. The inhaled aerosol particles had a mass median diameter of 3.1 micro m. Emitted dose was 67 +/- 13% (range 57-81%) of the calculated dose. CONCLUSION Our system is effective in delivering aerosolized PGI(2) to the alveolar-capillary interface, as indicated by significant oxygenation improvements soon after therapy commenced. The performance of the MiniHEART nebulizer varies from the manufacturer's specifications, which may alter the delivered dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Evaluation of Cell Penetrating Peptide Delivery System on HPV16E7 Expression in Three Types of Cell Line

Background: The poor permeability of the plasma and nuclear membranes to DNA plasmids are two major barriers for the development of these therapeutic molecules. Therefore, success in gene therapy approaches depends on the development of efficient and safe non-viral delivery systems. Objectives: The aim of this study was to investigate the in vitro delivery of plasmid DNA encoding HPV16 E7 gene...

متن کامل

Sodium Alginate/Starch Blends Loaded with Ciprofloxacin Hydrochloride as a Floating Drug Delivery System - In Vitro Evaluation

In the present study, Floating Drug Delivery Beads (FDDS) were prepared with sodium alginate/ starch blend as a matrix, sodium hydrogen carbonate as a pore forming agent, methyl cellulose as a binder and barium chloride solution as a hardening agent. In order to prepare the beads with different porosity and morphology the ratio between pore forming agent to polymer blend and ratio of the co...

متن کامل

In vitro and in vivo evaluation of a novel testosterone transdermal delivery system (TTDS) using palm oil base

Objective (s): Transdermal preparations for testosterone are becoming popular because of their unique advantages such as avoidance of first-pass effect, convenience, improved bioavailability, and reduction of systemic side effects. A novel testosterone transdermal delivery system (TDDS) was developed using a palm oil base called HAMINTM (a commercial product) and tested using in vitro and in vi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 48 8  شماره 

صفحات  -

تاریخ انتشار 2003