Contingency Analysis of Reduced 220 Kv Kptcl System Using Mat-lab Simulink Model

نویسنده

  • D. Kulkarni
چکیده

In the modern days the power system is becoming wide and complex. Contingency Analysis (CA) is critical in power system analysis. Due to the tremendous and yet increasing amount of data computed by CA, effective visualizations are needed to present the CA results to assist the system operators and engineers to comprehend the static security status of the system in a quick and intuitive manner. The desirable functionalities of such visualizations include showing the overall system security status, showing the severity levels of the contingencies in terms of their associated limit violations. Continuing interconnections of bulk power systems brought about by economic and environmental pressures has led to an increasingly complex system which must be operated closer to the limits of stability. This situation is worst when contingencies occur in the stressed network. This work presents a new technique for contingency analysis based on line flow analysis. Contingency analysis is performed considering the line and generator outage contingencies with different loading conditions in order to identify the effect of an increase in loading to critical line and generator outages. The proposed technique is demonstrated considering 220kV KPTCL system for which the simulink model is developed to evaluate contingency. This will helps to identify the severity level of the system & weak cluster of system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Very Fast Transient over voltages at high frequency in a Gas Insulated Substation during switching operations

Due to the opening or closing of circuit breakers and disconnect switches in Gas Insulated Substations (GIS), especially in the pumped storage power stations, Very Fast Transient Over-voltages (VFTO) are generated. This paper describes the 500 kV and 750 kV GIS. The variations of VFTO magnitudes at different points in 500 kV and 750 kV GIS during different switching operations have been calcula...

متن کامل

Design and Simulation of Cascaded H-Bridge Multilevel Inverter Based DSTATCOM

AbstractThis paper presents an investigation of five-Level Cascaded H – bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses. The DSTATCOM helps to improve the power factor and eliminate t...

متن کامل

Load Forecasting by a Novel Technique Using Ann

Basically the active power demands at various load buses need to be estimated ahead of time in order to plan the generation and distribution schedules, for contingency analysis and also for monitoring the system security. A great deal of attention has been given in recent years to the question of setting up the demand models for the individual appliances and their impact on the aggregated deman...

متن کامل

Transient Behavior of Doubly Fed Induction Generator Using Simulink Model in Wind Energy Conversion System

In this paper, transient behaviours of the Doubly Fed Induction Generator using Simulink model is demonstrated. A mathematical model based on d-q transformation i.e. stator phase currents, rotor currents, stator flux linkages,rotor flux linkages ,instantaneous power electromagnetic torque is also presented. In this paper 9 MW wind farm consisting of six 1.5 MW wind turbines connected to a 25 kV...

متن کامل

Design and Implementation of a Cascaded H-bridge Multilevel Inverter by Fpga Controller for Photo Voltaic Application

Multilevel Inverters are emerging technology playing a vital role in power electronics, Electric drive systems and Power systems etc. Here new multilevel topology is discussed. Cascaded HBridge (CHB) 7 level inverter is designed using Simulink, finally it is simulated and inverter switching signals are controlled using FPGA controller. H-bridges are connected seriously to achieve 7 level output...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012