Optimizing brain tissue contrast with EPI: a simulated annealing approach.
نویسندگان
چکیده
A new magnetization preparation and image acquisition scheme was developed to obtain high-resolution brain images with optimal tissue contrast. The pulse sequence was derived from an optimization process using simulated annealing, without prior assumptions with regard to the number of radiofrequency (RF) pulses and flip angles. The resulting scheme combined two inversion pulses with the acquisition of three images with varying contrast. The combination of the three images allowed separation of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) based on T1, contrast. It also enabled the correction of small errors in the initial T1 estimates in postprocessing. The use of three-dimensional (3D) sensitivity-encoded (SENSE) echo-planar imaging (EPI) for image acquisition made it possible to achieve a 1.15(3) mm3 isotropic resolution within a scan time of 10 min 21 s. The cortical GM signal-to-noise ratio (SNR) in the calculated GM-only image varied between 30 and 100. The novel technique was evaluated in combination with blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) on human subjects, and provided for excellent coregistration of anatomical and functional data.
منابع مشابه
Using and comparing metaheuristic algorithms for optimizing bidding strategy viewpoint of profit maximization of generators
With the formation of the competitive electricity markets in the world, optimization of bidding strategies has become one of the main discussions in studies related to market designing. Market design is challenged by multiple objectives that need to be satisfied. The solution of those multi-objective problems is searched often over the combined strategy space, and thus requires the simultaneous...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملSimulated Annealing Approach for Solving Bilevel Programming Problem
Bilevel programming, a tool for modeling decentralized decision problems, consists of the objective of the leader at its first level and that of the follower at the second level. Bilevel programming has been proved to be an Np-hard problem. Numerous algorithms have been developed for solving bilevel programming problems. These algorithms lack the required efficiency for solving a real problem. ...
متن کاملOptimizing location, routing and inventory decisions in an integrated supply chain network under uncertainty
This study extends a mathematical model that integrates the location, allocation, inventory replenishment and routing decisions simultaneously. To cope with inherent uncertainty of parameters, we implement a continuous-time Markov process and derive the performance measures of the system. Using the obtained results, the problem is formulated as a mixed integer nonlinear programing model (MINLP)...
متن کاملA simulated annealing approach to solve the network design of one-way streets: case of Shiraz network
This study is devoted to the formulation of the network design problem of one-way streets and the application of simulated annealing (SA) algorithm to solve this problem for a large real network. It discusses some points of views on one-way street networks, the objective function used for design, the way in which design constraints may be considered, and the traffic problems concerning one-way ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 54 2 شماره
صفحات -
تاریخ انتشار 2005