JBO LETTERS Combined multiphoton microscopy and optical coherence tomography using a 12-fs broadband source
نویسندگان
چکیده
A 12-fs broadband 100-nm source is used to combine multiphoton microscopy MPM and optical coherence tomography OCT in a single platform. An ultrafast Ti:sapphire laser simultaneously provides short pulses necessary for efficient MPM excitation and the broad bandwidth required for high-resolution OCT. Using 0.3m microspheres and a 63 , 0.95 numerical aperture objective, we demonstrate that MPM and OCT channels are coregistered with lateral resolution of approximately 0.5 m and axial resolution of approximately 1.5 m. Preliminary studies of a 3-D organotypic epithelial tissue model show that multiphoton images of fluorescence and second harmonic signals are derived from cellular and extracellular matrix structures, respectively, while OCT images are generated from scattering interfaces due to tissue variations in refractive index. The combined MPM/OCT microscope is capable of providing simultaneous functional and structural information from cells and extracellular matrix and is potentially a powerful tool for studying biological processes in thick tissues. © 2006 Society of Photo-Optical Instrumentation Engineers. DOI: 10.1117/1.2193428
منابع مشابه
Combined multiphoton microscopy and optical coherence tomography using a 12-fs broadband source.
A 12-fs broadband (100-nm) source is used to combine multiphoton microscopy (MPM) and optical coherence tomography (OCT) in a single platform. An ultrafast Ti:sapphire laser simultaneously provides short pulses necessary for efficient MPM excitation and the broad bandwidth required for high-resolution OCT. Using 0.3-microm microspheres and a 63x, 0.95 numerical aperture objective, we demonstrat...
متن کاملImaging subcellular scattering contrast by using combined optical coherence and multiphoton microscopy.
The structural origin of scattering contrast from single cells is examined by using a combined optical coherence and multiphoton microscope based on a 12 fs Ti:sapphire source and a 0.95 NA objective. High-resolution coherence-gated scattering images from single cells are coregistered and compared with two-photon-excited fluorescence images. Scattering contrast is observed from mitochondria, pl...
متن کاملSimultaneous optical coherence tomography and autofluorescence microscopy with a single light source.
We have accomplished simultaneous spectral domain optical coherence tomography (SD-OCT) and autofluorescence (AF) microscopy with a broadband light source centered at 415 nm. The light source was provided by frequency-doubling of an ultra-fast broadband Ti:Sapphire laser. With a bandwidth of 8 nm, the visible SD-OCT achieved a depth resolution of ~12 μm. Since the two imaging modalities are pr...
متن کاملJBO LETTERS Effect of pulse duration on two-photon excited fluorescence and second harmonic generation in nonlinear optical microscopy
We have developed a multiphoton microscopy MPM system using a 12-fs Ti:sapphire laser with adjustable dispersion precompensation in order to examine the impact of pulse duration on nonlinear optical signals. The efficiencies of two-photon-excited fluorescence TPEF and second harmonic generation SHG were studied for various pulse durations, measured at the sample, ranging from 400 fs to sub-20 f...
متن کاملSpectroscopic spectral-domain optical coherence microscopy.
The spectroscopic content within optical coherence tomography (OCT) data can provide a wealth of information. Spectroscopic OCT methods are frequently limited by time-frequency trade-offs that limit high spectral and spatial resolution simultaneously. We present spectroscopic spectral-domain optical coherence microscopy performed with a multimodality microscope. Restricting the spatial extent o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006