Graded exercise testing (GXT), per a cycle-ergometer (CE), offers safety and monitoring advantages over treadmill (TM) GXT. Unfortunately, CE-VO2max and some other cardiorespiratory (CR) variables are frequently lower than TM-GXT values. It has been difficult to compare TM and CE-GXT values. However, it was hypothesized that standing towards the conclusion of the CE-GXT (Stand-CE) might increase CE values to those equal to TM-GXT. If Stand-CE and TM-GXT CR values were equal, Stand-CE-GXT could become the method of choice for GXT for the general population. The purpose of this investigation was to investigate the effect of Stand-CE on CR variables. An intentionally diverse sample (N = 34, 24 males and 10 females, aged 18-54 y, with VO2max values 25-76 ml/kg/min) representing the "apparently healthy" general population participated. Volunteers completed two GXT trials, one per TM (Bruce protocol) and the other per a MET-TM-matched CE-GXT where initially seated participants stood and pedaled after their respiratory exchange ratio (RER) reached 1.0. Eighteen participants underwent a third MET-TM-matched trial where they remained seated throughout GXT (Sit-CE). Trials were counter-balanced with at least 48 h between GXT. There were significant statistical differences (p < 0.05) between TM and Stand-CE per matched-samples T-test (N = 34) on the following variables: VEmax (TM = 115 ± 24.4 l/min, Stand-CE = 99.4 ± 28.1), VCO2max (TM = 4.26 ± 0.9 l/min, Stand-CE = 3.56 ± 0.84), VO2max (TM = 44.9 ± 9.1 ml/kg/min, Stand-CE = 39.3 ± 9.0), METSmax (TM = 12.8 ± 2.6 METS, Stand-CE = 11.2 ± 2.5), and HRmax (TM = 175 ± 13 bpm, Stand-CE = 166 ± 12). One-way repeated measures ANOVA (N = 18) demonstrated no statistical differences among all trials: VEmax (TM = 112.8 ± 25.3 l/min, Stand-CE = 102.3 ± 25.2, Sit-CE = 107.3 ± 33.1), VCO2max (TM = 4.17 ± 0.99 l/min, Stand-CE = 3.62 ± 0.80, Sit-CE = 3.55 ± 0.83), VO2max (TM = 47.1 ± 9.8 ml/kg/min, Stand-CE = 42.0 ± 9.0, Sit-CE = 43.3 ± 8.9), METSmax (TM = 13.5 ± 2.8 METS, Stand-CE = 12.0 ± 2.6, Sit-CE = 12.4 ± 2.5), and HRmax (TM = 176 ± 13 bpm, Stand-CE = 171 ± 12, Sit-CE = 173 ± 11). Results of this investigation suggest that TM-GXT CR values are larger than Stand-CE, and Stand-CE values are not different from Sit-CE. Future studies will test validity of these findings per gender, aerobic training status, in populations that are highly skilled with TM and CE (tri-athletes), children, the elderly, and diseased populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Submaximal cardiopulmonary thresholds on a robotics-assisted tilt table, a cycle and a treadmill: a comparative analysis

BACKGROUND The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmo...

متن کامل

Physiological responses to linear treadmill and cycle ergometer exercise in COPD.

Incremental cardiopulmonary exercise testing work rate ideally increases linearly to the subject's tolerance within approximately 10 min. Widely used treadmill protocols often yield shorter exercise times in debilitated patients. We compared a recently described treadmill protocol featuring linear work rate increase, weight adjustments and a priori exercise tolerance estimates with standard cyc...

متن کامل

Moderate dose of watercress and red radish does not reduce oxygen consumption during graded exhaustive exercise

Objective: Very recent studies have reported positive effects of dietary nitrate on the oxygen consumption during exercise. This research aimed to study the effect of moderate dose of high-nitrate vegetables, watercress (Nasturtium officinale) and red radish (Raphanus sativus) compared with a control group on the incremental treadmill exercise test following a standard Bruce protocol controlled...

متن کامل

Cardiorespiratory responses to standing arm ergometry in patients with ischemic heart disease. Comparison with the results of treadmill exercise.

To compare cardiorespiratory responses to standing arm ergometry and treadmill exercise, two graded exercise stress tests were performed in 30 patients with ischemic heart disease (IHD). Cardiac catheterization and expired gas analyses were also done. Standing arm ergometry was discontinued because of arm fatigue in 15 (50%) patients, whereas treadmill exercise was stopped due to leg fatigue in...

متن کامل

Comparison of the electrocardiographic changes induced by maximam exercise testing with treadmill and cycle ergometer.

Maximum exercise testing using treadmill walking and cycle ergometry was compared in 40 male patients who had suffered a myocardial infarction in the preceeding twelve months. Maximum oxygen uptake was on average 17% greater in the treadmill than the cycle test and maximum heart rate was also higher, but the rate pressure product (RPP) was a similar due to a higher blood pressure in the cycle e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010