Lack of robustness of textural measures obtained from 3D brain tumor MRIs impose a need for standardization

نویسندگان

  • David Molina
  • Julián Pérez-Beteta
  • Alicia Martínez-González
  • Juan Martino
  • Carlos Velasquez
  • Estanislao Arana
  • Víctor M Pérez-García
چکیده

PURPOSE Textural measures have been widely explored as imaging biomarkers in cancer. However, their robustness under dynamic range and spatial resolution changes in brain 3D magnetic resonance images (MRI) has not been assessed. The aim of this work was to study potential variations of textural measures due to changes in MRI protocols. MATERIALS AND METHODS Twenty patients harboring glioblastoma with pretreatment 3D T1-weighted MRIs were included in the study. Four different spatial resolution combinations and three dynamic ranges were studied for each patient. Sixteen three-dimensional textural heterogeneity measures were computed for each patient and configuration including co-occurrence matrices (CM) features and run-length matrices (RLM) features. The coefficient of variation was used to assess the robustness of the measures in two series of experiments corresponding to (i) changing the dynamic range and (ii) changing the matrix size. RESULTS No textural measures were robust under dynamic range changes. Entropy was the only textural feature robust under spatial resolution changes (coefficient of variation under 10% in all cases). CONCLUSION Textural measures of three-dimensional brain tumor images are not robust neither under dynamic range nor under matrix size changes. Standards should be harmonized to use textural features as imaging biomarkers in radiomic-based studies. The implications of this work go beyond the specific tumor type studied here and pose the need for standardization in textural feature calculation of oncological images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrating fMRI data into 3D conventional radiotherapy treatmentplanning of brain tumors

Introduction: This study was aimed to investigate the beneficial effects of functional magnetic resonance imaging (fMRI) data in treatment planning for patients with CNS tumors in order to decrease the injury of functional regions of the brain followed by increase in life quality and survival of patients. This study pursues a novel approach in planning for the treatment of brai...

متن کامل

Towards safe and effective phytomedicines:the need for standardization

Over the past 20 years herbal medicinal products have become a topic of increasing global importance, with both medical and economic implications. In developing countries in Africa and Asia, botanicals have always played a central role in healthcare. Data from WHO suggest that 65 to 80% of the populations in these countries depend on traditional and botanical medicines as the primary source of ...

متن کامل

Measuring midline dose without build-up cap for patients with brain tumor undergoing 15MV external radiotherapy by using EBT3 Gafchromic film

Introduction: The Purpose of this study has been measuring midline dose for the patients undergoing brain radiotherapy without any need to build-up cap. Materials and Methods: The study was performed on 28 patients with brain tumor undergoing 15 MV radiotherapy by a Siemens LINAC. To estimate the midline dose, the entrance and exit doses were calculated b...

متن کامل

Kernicterus in Two Generations: A Need for More Aggressive Preventive Measures

Bilirubin induced brain damage is still a common cause of morbidity and mortality in Nigerian infants. No much success has been recorded in decades despite the fact that brain damage from bilirubin toxicity in the newborn is easily preventable with affordable and effective means. We report a case of a newborn with acute bilirubin encephalopathy. This case was considered of interest because the ...

متن کامل

I-5: Semen Analysis - Clinical Laboratories; Is Standardization Applied?

Reduced semen quality is commonly claimed to be one of the main signs of male infertility and thus, analysis of semen is recommended as the cornerstone of a male fertility investigation. However, to control possible sources of physiological and methodological variation, and to generate reliable information on semen quality that can be accurately compared across different laboratories, semen ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017