A Fetal Electrocardiogram Signal Extraction Algorithm Based on Fast One-Unit Independent Component Analysis with Reference

نویسندگان

  • Yanfei Jia
  • Xiaodong Yang
چکیده

Fetal electrocardiogram (FECG) extraction is very important procedure for fetal health assessment. In this article, we propose a fast one-unit independent component analysis with reference (ICA-R) that is suitable to extract the FECG. Most previous ICA-R algorithms only focused on how to optimize the cost function of the ICA-R and payed little attention to the improvement of cost function. They did not fully take advantage of the prior information about the desired signal to improve the ICA-R. In this paper, we first use the kurtosis information of the desired FECG signal to simplify the non-Gaussian measurement function and then construct a new cost function by directly using a nonquadratic function of the extracted signal to measure its non-Gaussianity. The new cost function does not involve the computation of the difference between the function of the Gaussian random vector and that of the extracted signal, which is time consuming. Centering and whitening are also used to preprocess the observed signal to further reduce the computation complexity. While the proposed method has the same error performance as other improved one-unit ICA-R methods, it actually has lower computation complexity than those other methods. Simulations are performed separately on artificial and real-world electrocardiogram signals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Comparison Research of the FECG Signal Separation Based on the BSS Algorithm

Fetal Electrocardiogram (FECG) is a weak signal through placing the electrodes upon the maternal belly surface to indirectly monitor, which contains all the forms of jamming signal. So, how to separate the FECG from the strong background interference has important value of clinical application. Independent Component Analysis (ICA) is a kind of developed new Blind Source Separation (BSS) technol...

متن کامل

A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...

متن کامل

Sensor Array and Electrode Selection for Non-invasive Fetal Electrocardiogram Extraction by Independent Component Analysis

Recently, non-invasive techniques to measure the fetal electrocardiogram (FECG) signal have given very promising results. However, the important question of the number and the location of the external sensors has been often discarded. In this paper, an electrode-array approach is proposed; it is combined with a sensor selection algorithm using a mutual information criterion. The sensor selectio...

متن کامل

Comparative Analysis of Wavelet-based Feature Extraction for Intramuscular EMG Signal Decomposition

Background: Electromyographic (EMG) signal decomposition is the process by which an EMG signal is decomposed into its constituent motor unit potential trains (MUPTs). A major step in EMG decomposition is feature extraction in which each detected motor unit potential (MUP) is represented by a feature vector. As with any other pattern recognition system, feature extraction has a significant impac...

متن کامل

Fetal ECG Extraction by Combining Single-Channel SVD and Cyclostationarity-Based Blind Source Separation

Fetal Electrocardiogram (FECG) can provide important clinical information for the assessment of fetal well-being. However, the extraction of FECG from the maternal abdominal wall remains an open problem due to various kinds of interferences and noises, where the maternal Electrocardiogram (MECG) is the dominant source of interference. In this study, a novel FECG extraction framework by combinin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016