Automated interhemispheric surface extraction in T1-weighted MRI using intensity and symmetry information
نویسندگان
چکیده
BACKGROUND Localizing the human interhemispheric region is of interest in image analysis mainly because it can be used for hemisphere separation and as a preprocessing step for interhemispheric structure localization. Many existing methods focus on only one of these applications. NEW METHOD Here a new Intensity and Symmetry based Interhemispheric Surface extraction method (ISIS) that enables both applications is presented. A combination of voxel intensity and local symmetry is used to optimize a surface from T1-weighted MRI. RESULTS ISIS was evaluated in regard to cerebral hemisphere separation using manual segmentations. It was also evaluated in regard to being a preprocessing step for interhemispheric structure localization using manually placed landmarks. COMPARISON WITH EXISTING METHODS Results were compared to cerebral hemisphere separations by BrainVisa and Freesurfer as well as to a midsagittal plane (MSP) extraction method. ISIS had less misclassified voxels than BrainVisa (ISIS: 0.119±0.114%, BrainVisa: 0.138±0.084%, p=0.020). Freesurfer had less misclassified voxels than ISIS for one dataset (ISIS: 0.063±0.056%, Freesurfer: 0.049±0.044%, p=0.019), but failed to produce usable results for another. Total voxel distance from all manual landmarks did not differ significantly between ISIS and the MSP method (ISIS: 4.00±1.88, MSP: 4.47±4.97). CONCLUSIONS ISIS was found successful in both cerebral hemisphere separation and as a preprocessing step for interhemispheric structure localization. It needs no time consuming preprocessing and extracts the interhemispheric surface in less than 30 s.
منابع مشابه
Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inver-sion recovery T1-weighted MRI
Background: Ultrasmallsuperparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images. Methods : D...
متن کاملI-41: Imaging Strategy for Diagnosis of Adnexal Masses Including US,CT Scan and MRI
Adnexal masses are spectrum of diseases from benign non neoplastic and neoplastic masses to malignant neoplasms. Endovaginal ultrasonography (US) is the fisrt and invaluable modality for assessment of adnexal masses because it is available and has a high negative predictive value. Important morphologic features are solid (vascularized) tissue, vascular and thick septations, and papillary projec...
متن کاملSurface Coil Intensity Correction in Magnetic Resonance Imaging in Spinal Metastases
OBJECTIVE To evaluate the clinical application of phased-array surface coil intensity correction in magnetic resonance imaging (MRI) in spinal metastases. METHODS 3 phantoms and 50 patients with a corresponding total number of 80 spinal metastases were included in this study. Fast spin echo T1- and T2- weighted MRI with and without surface coil intensity correction was routinely performed for...
متن کاملAnatomical Landmark Based Registration of Contrast Enhanced T1-Weighted MR Images
In many problems involving multiple image analysis, an image registration step is required. One such problem appears in brain tumor imaging, where baseline and follow-up image volumes from a tumor patient are often to-be compared. Nature of the registration for a change detection problem in brain tumor growth analysis is usually rigid or affine. Contrast enhanced T1-weighted MR images are widel...
متن کاملPotential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times
Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Neuroscience Methods
دوره 222 شماره
صفحات -
تاریخ انتشار 2014