Haptic Feedback in a Telepresence System for Endoscopic Heart Surgery
نویسندگان
چکیده
The implementation of telemanipulator systems for cardiac surgery enabled heart surgeons to perform delicate minimally invasive procedures with high precision under stereoscopic view. At present, commercially available systems do not provide force-feedback or Cartesian control for the operating surgeon. The lack of haptic feedback may cause damage to tissue and can cause breaks of suture material. In addition, minimally invasive procedures are very tiring for the surgeon due to the need for visual compensation for the missing force feedback. While a lack of Cartesian control of the end effectors is acceptable for surgeons (because every movement is visually supervised), it prevents research on partial automation. In order to improve this situation, we have built an experimental telemanipulator for endoscopic surgery that provides both force-feedback (in order to improve the feeling of immersion) and Cartesian control as a prerequisite for automation. In this article, we focus on the inclusion of force feedback and its evaluation. We completed our first bimanual system in early 2003 (EndoPAR Endoscopic Partial Autonomous Robot). Each robot arm consists of a standard robot and a surgical instrument, hence providing eight DOF that enable free manipulation via trocar kinematics. Based on the experience with this system, we introduced an improved version in early 2005. The new ARAMIS system (Autonomous Robot Assisted Minimally Invasive Surgery) has four multi-purpose robotic arms mounted on a gantry above the working space. Again, the arms are controlled by two force-feedback devices, and 3D vision is provided. In addition, all surgical instruments have been equipped with strain gauge force sensors that can measure forces along all translational directions of the instrument’s shaft. Force-feedback of this system was evaluated in a scenario of robotic heart surgery, which offers an impression very similar to the standard, open procedures with high immersion. It enables the surgeon to palpate arteriosclerosis, to tie surgical knots with real suture material, and to feel the rupture of suture material. Therefore, the hypothesis that haptic feedback in the form of sensory substitution facilitates performance of surgical tasks was evaluated on the experimental platform described in the article (on the EndoPAR version). In addition, a further hypothesis was explored: The high fatigue of surgeons during and after robotic operations may be caused by visual compensation due to the lack of force-feedback (Thompson, J., Ottensmeier, M., & Sheridan, T. 1999. Human Factors in Telesurgery, Telmed Journal, 5 (2) 129–137.). *Correspondence to [email protected]
منابع مشابه
Evaluation of haptic in robotic heart surgery
The introduction of telemanipulator systems into cardiac surgery enables the heart surgeon to perform sophisticated mini-invasive and endoscopic procedures with high precision under stereoscopic view. At present, the commercially available robotic surgical systems do not dispose of force feedback for the operating surgeon. The lack of haptic (force or tactile) feedback causes damage of tissue a...
متن کاملHaptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector.
Conventional endoscopic surgery has some drawbacks that can be addressed by using robots. The robotic systems used for surgery are still in their infancy. A major deficiency is the lack of haptic feedback to the surgeon. In this paper, the benefits of haptic feedback in robot-assisted surgery are discussed. A novel robotic end-effector is then described that meets the requirements of endoscopic...
متن کاملTemporal perception of visual-haptic events in multimodal telepresence system
Multidomal telepresence systems have been used in remote or hazardous environments, such as telesurgery, orbit or underwater teleoperation, etc. (Ballantyne, 2002; Draper et al., 1998; Hirzinger et al., 1993). In a typical teleoperation task, local action commands are transmitted to a remote teleoperator, which then executes the commands and sends back multimodal sensory information, such as vi...
متن کاملThe capability of haptic feedback as additional sensory quality for robotic heart surgery
The implementation of telemanipulator systems into cardiac surgery enabled the heart surgeon to perform sophisticated minimally invasive and endoscopic procedures with high precision under stereoscopic view. At present, the commercially available robotic surgical systems do not provide force feedback for the operating surgeon. The lack of tactile feedback may cause damage of tissue and bending ...
متن کاملThe Must-Have in Robotic Heart Surgery: Haptic Feedback
The minimally invasive endoscopic surgery was introduced in the late 1980s in the abdominal surgery as revolutionary surgical technique (Voges et al., 1997). Surgeons no longer needed to physically place their hands within the body to perform an operation. In minimal invasive surgery, instruments and viewing equipments are inserted into the body through small incisions. Long manipulators are us...