Validation of a 16-locus fluorescent multiplex system.

نویسندگان

  • Benjamin E Krenke
  • Allan Tereba
  • Stacey J Anderson
  • Eric Buel
  • Sherry Culhane
  • Carla J Finis
  • Christine S Tomsey
  • Jeffrey M Zachetti
  • Arni Masibay
  • Dawn R Rabbach
  • Elizabeth A Amiott
  • Cynthia J Sprecher
چکیده

STR multiplexes have been indispensable for the efficient genotyping of forensic samples. The PowerPlex 16 System contains the coreCODIS loci, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, THOI, TPOX, vWA, the sex determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. This multiplex satisfies the locus requirements for most national databases and is the most efficient currently available system due to its single PCR amplification. To provide the groundwork for judicial acceptance, including the publication of primer sequences, and to evaluate laboratory-to-laboratory variation, a developmental validation for casework on this commercially available system was performed in 24 laboratories and produced the following conclusions. Amplification was reliable on a variety of thermal cyclers and product could be analyzed on either an ABI PRISM 310 Genetic Analyzer or an ABI PRISM 377 DNA Sequencer. Genotyping using single source samples was consistent between 0.25 and 2 ng of input DNA template with a few laboratories obtaining complete genotypes at 0.0625 ng. However, heterozygote allele imbalance (<60% peak height balance) caused by stochastic effects was observed at a rate of 13% with 0.125 ng DNA and 22% at 0.0625 ng DNA. Mixture analyses were done using a total of 1 ng of DNA template. Most alleles were detected in mixtures of 4 to 1 and some minor alleles were detected in mixtures of 19 to 1. Optimum amplification cycle number was dependent on the sensitivity of the detection instrument used and could also be adjusted to accommodate larger amounts of DNA on solid supports such as FTA paper. Reaction conditions including volume, annealing temperature, and concentrations of primer, AmpliTaq Gold, and magnesium were shown to be optimal yet robust enough to withstand moderate variations without affecting genotype analysis. Environmental, matrix and standard source analyses revealed an ability to obtain complete genotypes in all sample types except those exposed to 80 degrees C for 12-48 days. Finally, comparison of genotype results from the PowerPlex 16 System with other commercially available systems on non-probative reference and forensic samples showed consistent results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of highly polymorphic fluorescent multiplex short tandem repeat systems using two generations of DNA sequencers.

Validation studies are a crucial requirement before implementation of new genetic typing systems for clinical diagnostics or forensic identity. Two different fluorescence-based multiplex DNA profiling systems composed of amelogenin, HumD21S11 and HumFGA (referred to as multiplex 1A), and HumD3S1358, HumD21S11 and HumFGA (multiplex 1B) have been evaluated for use in forensic identification using...

متن کامل

Multiplex allele-specific fluorescent PCR for haplotyping the IVS8 (TG)m(T)n locus in the CFTR gene.

BACKGROUND Precise genotyping of the intron 8 poly(TG) and poly(T) tracts of the cystic fibrosis transmembrane conductance regulator (CFTR) gene is of clinical relevance in CFTR pathology. The (TG)(m) locus influences the penetrance of the (T)(5) allele, which may be associated with male infertility by congenital bilateral absence of the vas deferens (CBAVD) or other CFTR-related disorders (CFT...

متن کامل

Fluorescence imaging in human identity testing.

We have investigated the use of fluorescence detection and the FluorImager S1 System (Molecular Dynamics) for analyzing a comprehensive set of human DNA typing tests. We used an alkaline phosphatase-conjugated YNH24 oligonucleotide probe to the repeat-containing D2S44 locus to detect both alleles in 50 ng of human genomic DNA (0.025 amol) by Southern hybridization using a chemifluorescent subst...

متن کامل

Validation of multiplex immunofluorescence for use in analysis of tumour infiltrating lymphocytes

Background Multiplexed immunohistochemistry (IHC) has the potential to improve conventional IHC staining allowing for analysis of multiple cell phenotypes while maintaining spatial context. Automated multispectral image analysis and computer-based cell recognition make the process more attainable, but stringent validation of multiplex IHC is still required. Pertinently, multiplex IHC allows for...

متن کامل

Validation of a single tube fluorescent multiplex assay for simultaneous typing of 20 Y-STR loci

This paper describes a single tube assay for 20 fluorescent labelled Y-STR loci, which is rapid and robust state-of-art multiplex system. Reaction conditions, including annealing temperature, concentration of primers, magnesium and template DNA, DNA polymerase and reaction volume, were optimised to yield robust amplification. The assay could withstand moderate fluctuations in reaction parameter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of forensic sciences

دوره 47 4  شماره 

صفحات  -

تاریخ انتشار 2002