Evaluation of the stability of the stereotactic Leksell Frame G in Gamma Knife radiosurgery

نویسندگان

  • Alvaro Rojas‐Villabona
  • Katherine Miszkiel
  • Neil Kitchen
  • Rolf Jäger
  • Ian Paddick
چکیده

The purpose of this study was to evaluate the stability of the Leksell Frame G in Gamma Knife radiosurgery (GKR). Forty patients undergoing GKR underwent pretreatment stereotactic MRI for GKR planning and stereotactic CT immediately after GKR. The stereotactic coordinates of four anatomical landmarks (cochlear apertures and the summits of the anterior post of the superior semicircular canals, bilaterally) were measured by two evaluators on two separate occasions in the pre-treatment MRI and post-treatment CT scans and the absolute distance between the observations is reported. The measurement method was validated with an indepen-dent group of patients who underwent both stereotactic MRI and CT imaging before treatment (negative controls; n: 5). Patients undergoing GKR for arteriovenous malformations (AVM) also underwent digital subtraction angiography (DSA), which could result in extra stresses on the frame. The distance between landmark local-ization in the scans for the negative control group (0.63 mm; 95% CI: 0.57-0.70; SD: 0.29) represents the overall consistency of the evaluation method and provides an estimate of the minimum displacement that could be detected by the study. Two patients in the study group had the fiducial indicator box accidentally misplaced at post-treatment CT scanning. This simulated the scenario of a frame displacement, and these cases were used as positive controls to demonstrate that the evaluation method is capable of detecting a discrepancy between the MRI and CT scans, if there was one. The mean distance between the location of the landmarks in the pretreatment MRI and post-treatment CT scans for the study group was 0.71 mm (95% CI: 0.68-0.74; SD:0.32), which was not statistically different from the over-all uncertainty of the evaluation method observed in the negative control group (p = 0.06). The subgroup of patients with AVM (n: 9), who also underwent DSA, showed a statistically significant difference between the location of the landmarks compared to subjects with no additional imaging: 0.78 mm (95% CI: 0.72-0.84) vs. 0.69 mm (95% CI: 0.66-0.72), p = 0.016. This is however a minimal differ-ence (0.1 mm) and the mean difference in landmark location for each AVM patient remained submillimeter. This study demonstrates submillimeter stability of the Leksell Frame G in GKR throughout the treatment procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of stability of stereotactic space defined by cone‐beam CT for the Leksell Gamma Knife Icon

The Gamma Knife Icon comes with an integrated cone-beam CT (CBCT) for image-guided stereotactic treatment deliveries. The CBCT can be used for defining the Leksell stereotactic space using imaging without the need for the traditional invasive frame system, and this allows also for frameless thermoplastic mask stereotactic treatments (single or fractionated) with the Gamma Knife unit. In this st...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

Useful Base Plate to Support the Head during Leksell Skull Frame Placement in Gamma Knife Perfexion Radiosurgery

We developed an original base plate to support both the patient's head and a Leksell stereotactic skull frame during frame placement in the supine position. The base plate is made of transparent acrylic board with holes at the posterior posts for injection of local anesthetics and maneuver of fixation screws through them. A stable and comfortable position of the patient's head in a supine posit...

متن کامل

Image-guided Radiosurgery Using the Gamma Knife

Image guided brain surgery became a reality in the mid-1970s after the introduction of the fi rst methods to obtain axial imaging using computed tomography (CT) [9]. The recognition of cranial disease much earlier in its clinical course prompted the need for concomitant minimally invasive technologies to both diagnose and to treat the newly recognized brain tumors and vascular malformations. Su...

متن کامل

Physics of rotating gamma systems for stereotactic radiosurgery.

PURPOSE The purpose of this study was to evaluate the characteristics of a new rotating gamma system for stereotactic radiosurgery by comparison with a well accepted system. METHODS AND MATERIALS A novel gamma unit for stereotactic radiosurgery has been developed and distributed to 15 hospitals in China. The unit contains 30 cobalt-60 gamma radiation sources with initial activity of 200 Ci (7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016