The limited utility of electrocardiography variables used to predict arrhythmia in psychotropic drug overdose

نویسندگان

  • Nicholas A Buckley
  • Stephan Chevalier
  • I Anne Leditschke
  • Dianne L O'Connell
  • James Leitch
  • Susan M Pond
چکیده

OBJECTIVE The aim of the present study was to examine the relationship between serious arrhythmias in patients with psychotropic drug overdose and electrocardiography (ECG) findings that have been suggested previously to predict this complication. METHODS Thirty-nine patients with serious arrhythmias (ventricular tachycardia, supraventricular tachycardia or cardiac arrest) after tricyclic antidepressant overdose or thioridazine overdose were compared with 117 controls with clinically significant overdose matched to each case for the drug ingested. These patients with psychotropic drug overdose had presented for treatment to the Department of Clinical Toxicology, Newcastle and to the Princess Alexandra Hospital, Brisbane. The heart rate, the QRS width, the QTc and QT intervals, the QT dispersion, and the R wave and R/S ratios in aVR on the initial ECGs were compared in cases and controls. RESULTS The cases had taken dothiepin (16 patients), doxepin (six patients), thioridazine (five patients), amitriptyline (five patients), nortriptyline (three patients), imipramine (one patient) and a combination of dothiepin and thioridazine (three patients). In 20 of the 39 patients with arrhythmias, the arrhythmia had been a presumed ventricular tachycardia. Of the other 19 patients, 15 patients had a supraventricular tachycardia, two patients had cardiac arrests (one asystole, one without ECG monitoring) and two patients had insufficient data recorded to make classification of the arrhythmias possible. The QRS was >/= 100 ms in 82% of cases but also in 76% of controls. QRS >/= 160 ms had a sensitivity of only 13% and occurred in 2% of controls. QRS > 120 ms, QTc > 500 and the R/S ratio in aVR appeared to have a stronger association with the occurrence of arrhythmia: QRS > 120 ms (odds ratio [OR], 3.56; 95% confidence interval [CI], 1.46-8.68), QTc > 500 (OR, 3.07; 95% CI, 1.33-7.07), and R/S ratio in aVR > 0.7 (OR, 16; 95% CI, 3.47-74). Excluding thioridazine overdoses and performing the analysis for tricyclic antidepressant overdoses alone gave increased odds ratios for QRS > 120 ms (OR, 4.83; 95% CI, 1.73-13.5) and QTc > 500 (OR, 4.5; 95% CI, 1.56-13) but had little effect on that for the R/S ratio in aVR > 0.7 (OR, 14.5; 95% CI, 3.10-68). CONCLUSION ECG measurements were generally weakly related to the occurrence of arrhythmia and should not be used as the sole criteria for risk assessment in tricyclic antidepressant overdose. The frequently recommended practice of using either QRS >/= 100 ms or QRS >/= 160 ms to predict arrhythmias is not supported by our study. R/S ratio in aVR > 0.7 was most strongly related to arrhythmia but had estimated positive and negative predictive values of only 41% and 95%, respectively. The use of these specific predictors in other drug overdoses is not recommended without specific studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methadone Overdose and Its Complications in Patients Admitted to ‎the Toxicology Emergency Ward of Baharloo Hospital of Tehran in ‎‎2011-2012‎

Background: To date, studies on methadone overdose in adults have not been ‎reported in Iran. Hence, this study was performed to determine the frequency of ‎methadone overdose and its associated complications in Baharloo Hospital of Tehran ‎between August 2011 and August 2012.‎ Methods: This cross-sectional study was done on 390 cases. All patients with ‎methadone overdoses and positive urine ...

متن کامل

Cardiac arrhythmia due to ledipasvir/sofosbuvir Iranian counterpart, commercially named as Ledibiox: A case report

Sofosbuvir is an antiviral drug that entirely revolutionized the treatment of hepatitis C. This drug has an Iranian commercial brand, which is known as Ledibiox. Several adverse events have been reported with this drug, including syncope, pancolitis, and exacerbated pulmonary arterial hypertension; however, arrhythmia rarely has been described through the literature. Here, we report a 40-year-o...

متن کامل

Validation of the Prognostic Utility of the Electrocardiogram for Acute Drug Overdose

BACKGROUND While it is certain that some emergency department patients with acute drug overdose suffer adverse cardiovascular events (ACVE), predicting ACVE is difficult. The prognostic utility of the ECG for heterogeneous drug overdose patients remains to be proven. This study was undertaken to validate previously derived features of the initial ECG associated with ACVE in this population. M...

متن کامل

Conservative Management of Dabigatran Overdose: Case Report and Review of Literature

Background: Direct thrombin inhibitors and factor Xa inhibitors are gaining popularity as alternatives to warfarin for patients requiring anticoagulation. Toxicity due to these medications is difficult to manage because overdose experience is very limited and there is no clear guidance on when or whether to use antidote in this setting. Case Presentation: A 50-year-old man with normal renal fu...

متن کامل

Clinical use of antidepressant therapy and associated cardiovascular risk

A number of different psychotropic agents have been associated with an increased risk of cardiovascular disease, and these relationships have been difficult to interpret due to the presence of confounding factors. Recently, there has been renewed interest in the potential for certain antidepressants to cause QT prolongation, which is a predisposing factor for arrhythmia. However, the optimum me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical Care

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2003