Biomechanical comparison of volar locked plate constructs using smooth and threaded locking pegs.

نویسندگان

  • Jeffrey Yao
  • Min Jung Park
  • Chirag S Patel
چکیده

The goal of this study was to determine whether there is any biomechanical difference in terms of construct strength with axial loading between volar fixed-angle locking plates with threaded locking vs smooth locking pegs. The control group comprised 7 cadaveric specimens with threaded locking pegs, and the test group comprised 7 cadaveric specimens from the same donor with smooth locking pegs. The DVR plate (Biomet, Warsaw, Indiana) was applied to the volar surface. A 15-mm dorsal wedge osteotomy was created near the level of Lister's tubercle. The radii were potted in polymethylmethacrylate for biomechanical testing. The loading protocol consisted of 3 parts: ramp loading, cyclic loading, and failure loading. The outcome measures of stiffness and failure were used to test the plates fixed with threaded and smooth locking pegs. When comparing each cycle, the difference in mean stiffness between threaded and smooth locking pegs was as follows: 122 N/mm, -9.09 N/mm, -14.7 N/mm, 49.4 N/mm, 57.4 N/mm, 71.9 N/mm, 52.3 N/mm, 35.8 N/mm. The difference in mean failure load between the threaded and smooth locking pegs was -11.3 N. There was no difference in stiffness throughout all cycles. Failure analysis showed no significant difference between the smooth (962 N) and threaded (951 N) locking pegs. The difference in stiffness between the 2 constructs (smooth minus threaded locking pegs) in ramp loading ranged from -122 to 15 N/mm. The results of this study showed no significant differences in stiffness and failure load between constructs consisting of threaded locking pegs or smooth locking pegs in the distal rows of the DVR distal radius volar locking plate. Based on the results of this study, there may be no benefit to using threaded locking pegs vs smooth locking pegs when treating distal radius fractures with a volar locking plate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a new intramedullary scaffold to volar plating for treatment of distal radius fractures.

OBJECTIVES To compare the biomechanical properties of a new nitinol intramedullary (IM) scaffold implant with those of volar plates for the treatment of dorsally comminuted extra-articular distal radius fractures using an established model. METHODS A dorsal wedge osteotomy was performed on a bone model to simulate a dorsally comminuted extra-articular distal radius fracture. This model was us...

متن کامل

Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.

PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...

متن کامل

A comparison of parallel and diverging screw angles in the stability of locked plate constructs.

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm(3)) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Biomechanical properties of fixed-angle volar distal radius plates under dynamic loading.

PURPOSE To evaluate and compare the biomechanical properties of 8 different locked fixed-angle volar distal radius plates under conditions designed to reflect forces seen in early fracture healing and postoperative rehabilitation. METHODS We evaluated the Acumed Acu-Loc (Acumed, Hillsboro, OR), Hand Innovations DVR (Hand Innovations, Miami, FL), SBi SCS volar distal radial plate (Small Bone I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2014