An improved white cell diluent for use with the Eel electronic blood cell counter.

نویسندگان

  • F TAYLOR
  • A G RICKARDS
چکیده

An improved white cell diluent for use with the Eel electronic counter is described. It possesses advantages over previously described diluents in the rapidity of its action as a red cell stromalysin and in its ability to conserve surviving leucocytes for long periods of time. These properties enable counts to be made either immediately after preparation of the suspension or several hours later. The diluent is equally suitable for use with capillary or venous blood samples. When used for counting leucocytes it has been found necessary to effect a minor modification to the machine whereby the light intensity is reduced by approximately one-half.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the Celloscope 401 electronic blood cell counter.

For counting erythrocytes the instrument was precise, with a mean coefficient of variation of 1.21%. Erythrocyte counts showed close agreement with results obtained on a Coulter A electronic counter of proven accuracy. When the Celloscope 401 was modified by the manufacturers to eliminate electrical interference from other laboratory equipment, satisfactory precision and accuracy for white cell...

متن کامل

Evaluation of total and differential white blood cell counts in workers exposed to lead

Introduction: Lead is a toxic heavy metal that has adverse health effects on blood parameters. About 80% of lead produced is used in batteries, especially vehicle batteries. Therefore, the present study aimed to assess the hematological changes, including total and differential white blood cell (WBC) counts in battery workers exposed to lead, and compare with the non-exposed group. Materials a...

متن کامل

کلوزاپین: انقلابی جدید در درمان شیزوفرنی

Clozapine is the first antipsycotic drug with a great efficacy. Thirty to fifty percent of treatment-resistant schizophrenics markedly improved with clozapine. Approximately, 25% of long-term patients, treated with clozapine, could be discharged. This improvement included negative as well as positive symptom areas. Clozapine produced no extrapyramidal side effects. Tardive dyskinesia, a major s...

متن کامل

Elevated white blood cell counts and risk of metabolic syndrome: a dose-response meta-analysis

Background and Aim: Elevated white blood cell count has been a known risk factor for cardiovascular diseases. Cardiometabolic diseases have some risk factors in common. Therefore, we assessed the association between elevated white blood cell counts and risk of metabolic syndrome using dose-response meta-analysis method. Materials & Methods: We searched for observational studies including white ...

متن کامل

Some problems in the use of the Coulter counter for erythrocyte total counts and volume distribution.

Normal erythrocytes were subject to swelling and some haemolysis when suspended in a NaCl-formaldehyde-Na(2)EDTA diluent of pH 4.9 for routine blood-cell counting in the Coulter counter. A phosphate-buffered saline of pH 7.4 was substituted and has proven satisfactory for total erythrocyte counts. Polyvinyltoluene latex was unsuitable for volume calibration of the counter, because of aggregatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1960