Alarms and human behaviour: implications for medical alarms.
نویسندگان
چکیده
Alarms are used in many clinical applications, but they are often less than optimal because the design and implementation of alarms has not always taken the cognitive capacity and processing mechanisms of the user into account. As a result alarms are frequently too loud, irritating, confusing, badly designed, and too numerous, resulting in them often being turned off and hindering, rather than enhancing, task performance. This paper reviews some of the main areas where it is essential to take account of the cognitive system of the user and behavioural processes more generally. Five central areas of concern are discussed: the number of alarms and ways that this might be reduced; false alarm rates and their impact on human responses; the design of alarms and the application of research into auditory cognition on design; intelligent alarm systems; and the proposals for alarm design set out in a recent worldwide medical alarms standard. In each area some background is given and the implications for alarm design and implementation outlined. The conclusion is that there are some indications that alarm design and implementation takes account of relevant research data, but that there is still some way to go before these findings are fully integrated and the situation is improved upon further.
منابع مشابه
A Petri-net Model for Operational Cycle in SCADA Systems
Supervisory control and data acquisition (SCADA) system monitors and controls industrial processes in critical infrastructures (CIs) and plays the vital role in maintaining the reliability of CIs such as power, oil, and gas system. In fact, SCADA system refers to the set of control process, which measures and monitors sensors in remote substations from a control center. These sensors usually ha...
متن کاملOverlapping Melodic Alarms Are Almost Indiscriminable
OBJECTIVE We explore how accurately and quickly nurses can identify melodic medical equipment alarms when no mnemonics are used, when alarms may overlap, and when concurrent tasks are performed. BACKGROUND The international standard IEC 60601-1-8 (International Electrotechnical Commission, 2005) has proposed simple melodies to distinguish seven alarm sources. Previous studies with nonmedical ...
متن کامل[Stimulus-response time to invasive blood pressure alarms: implications for the safety of critical-care patients].
Observational, descriptive, exploratory, case study with the objective of measuring the stimulus-response time of the team to alarms monitoring invasive blood pressure (IBP) and analyzing the implications of this time for the safety of the patient From January to March 2013, 60 hours of structured observation were conducted with registration of the alarms activated by IBP monitors in an adult I...
متن کاملAuditory Alarms, Medical Standards, and Urgency
A newly-released international standard for medical equipment alarms, IEC 60601-1-8, incorporates a long-standing suggestion that alarms should indicate their source through distinctive melodies. In this paper we examine this suggestion. We describe the proposed alarms, outline the history of the idea, and review recent research on the effectiveness of the alarms, some of it performed in our la...
متن کاملClinical Alarms in intensive care: implications of alarm fatigue for the safety of patients1
OBJECTIVES to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS a total of 426...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 97 1 شماره