Binuclear Schiff base complex of manganese(III) as a neutral carrier for a highly selective iodide electrode.

نویسندگان

  • Qin Zhao
  • Ruo Yuan
  • Yaqin Chai
  • Lan Xu
  • Jiancun Chen
  • Zhongxiu Zhang
چکیده

A new highly selective iodide electrode incorporating a binuclear manganese(III) complex, bis(salicylaldehyde-aminopropanol)dichloroaceticdimanganese(III) [Mn(III)(2)-BSAPDCA], as a neutral carrier is described. The electrode displays an anti-Hofmeister selectivity sequence: iodide >> perchlorate > salicylate > thiocyanate > nitrate > bromide > nitrite > chloride > sulfate. The excellent selectivity for iodide is related to a direct interaction between the central Mn(III) atom and iodide and a steric effect associated with the structure of the carrier, which is supported by UV spectroscopy and AC impedance techniques. The electrode exhibits a near-Nernstian potentiometric linear response range to iodide from 1.0 x 10(-1) to 2.0 x 10(-5) mol/L with a detection limit of 8.0 x 10(-6) mol/L and a slope of -60.3 mV/decade in pH 3.0 of phosphate buffer solutions at 20 degrees C. From a comparison of the potentiometric response characteristics between a binuclear manganese(III) complex, Mn(III)(2)-BSAPDCA, and a mononuclear manganese(III) complex, Mn(III)-BSAPB, an enhanced response towards iodide from a binuclear metallic complex-based electrode was observed. The electrode, based on binuclear manganese(III) complex, was successfully applied to the determination of inorganic total iodine in iodized table salt with satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The lim...

متن کامل

Al(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore

A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M  with Nernstian slope of 19...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

A Pair of Manganese(III) Schiff-Base Enantiomers: Synthesis, Crystal Structure and Magnetic Characterization

Based-on the quasi-planar tetra-dentate Schiff-base ligand, a pair of manganese(III) Schiff-base enantiomers formulated as {[Mn(R,R-3-MeOSalcy)(H2O)(CH3OH)]ClO4}2 (1) and {[Mn(S,S-3-MeOSalcy)(H2O)(CH3OH)]ClO4}2 (2) (3-MeOSalcy = N,N′-(1,2-cyclohexanediylethylene)bis(3-methoxysalicylideneiminato)dianion) ...

متن کامل

Manganese (M-selective PVC membrane electrode based on N-(2- picolinamido ethyl)-Picolinamide as ionophore

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 11  شماره 

صفحات  -

تاریخ انتشار 2007