Visual Evoked Cortical Potential (VECP) Elicited by Sinusoidal Gratings Controlled by Pseudo-Random Stimulation

نویسندگان

  • Carolina S. Araújo
  • Givago S. Souza
  • Bruno D. Gomes
  • Luiz Carlos L. Silveira
چکیده

The contributions of contrast detection mechanisms to the visual cortical evoked potential (VECP) have been investigated studying the contrast-response and spatial frequency-response functions. Previously, the use of m-sequences for stimulus control has been almost restricted to multifocal electrophysiology stimulation and, in some aspects, it substantially differs from conventional VECPs. Single stimulation with spatial contrast temporally controlled by m-sequences has not been extensively tested or compared to multifocal techniques. Our purpose was to evaluate the influence of spatial frequency and contrast of sinusoidal gratings on the VECP elicited by pseudo-random stimulation. Nine normal subjects were stimulated by achromatic sinusoidal gratings driven by pseudo random binary m-sequence at seven spatial frequencies (0.4-10 cpd) and three stimulus sizes (4°, 8°, and 16° of visual angle). At 8° subtence, six contrast levels were used (3.12-99%). The first order kernel (K1) did not provide a consistent measurable signal across spatial frequencies and contrasts that were tested-signal was very small or absent-while the second order kernel first (K2.1) and second (K2.2) slices exhibited reliable responses for the stimulus range. The main differences between results obtained with the K2.1 and K2.2 were in the contrast gain as measured in the amplitude versus contrast and amplitude versus spatial frequency functions. The results indicated that K2.1 was dominated by M-pathway, but for some stimulus condition some P-pathway contribution could be found, while the second slice reflected the P-pathway contribution. The present work extended previous findings of the visual pathways contribution to VECP elicited by pseudorandom stimulation for a wider range of spatial frequencies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical responses elicited by luminance and compound stimuli modulated by pseudo-random sequences: comparison between normal trichromats and congenital red-green color blinds

Conventional pattern-reversal visual evoked cortical potential (VECP) shows positivity for luminance and chromatic equiluminant stimuli while conventional pattern-onset VECP shows positivity for luminance pattern-onset and negativity for chromatic pattern-onset. We evaluated how the presentation mode affects VECPs elicited by luminance and compound (luminance plus chromatic) pseudo-random stimu...

متن کامل

Grating test of contrast sensitivity in patients with Minamata disease.

Thirty cases of Minamata disease caused by methyl mercury poisoning with the lesion mainly at the occipital cortex were selected and their spatial contrast sensitivity of vision was examined by the Arden grating chart. At the same time their visual acuity, visual field, and visual evoked cortical potential (VECP) were also investigated. In all cases the results of the Arden test indicated abnor...

متن کامل

Canine visual acuity: retinal and cortical field potentials evoked by pattern stimulation.

The visual acuities (i.e., visual thresholds for pattern detection) of four dogs under neuromuscular block were measured using visually evoked cortical potentials (VECP) and/or pattern-evoked retinal potentials (PERR). Stimuli were phase-reversing square-wave gratings with a mean luminance of 86 cd/m2 and 70% contrast. The mean of the VECP thresholds of two dogs tested was 12.59 cycles per degr...

متن کامل

Visual Dysfunction of Type I and VI Mucopolysaccharidosis Patients Evaluated with Visual Evoked Cortical Potential

PURPOSE To evaluate the visual system of patients suffering from type I or VI mucopolysaccharidosis (MPS) by recording the visual evoked cortical potential (VECP). METHODS Two patients with MPS VI and 2 patients with MPS I were tested before and after enzyme replacement therapy (ERT). A control group of 20 subjects was tested for statistical comparison. VECP was elicited by monocular stimulat...

متن کامل

Visual-evoked responses elicited by the onset and offset of sinusoidal gratings: latency, waveform, and topographic characteristics.

Transient evoked potentials (VERs) elicited by the onset and offset of sinusoidal gratings have been investigated. Results indicated that an increase in amplitude and a decrease in latency characteristics of VER occur as monotonic functions of increasing contrast. The latencies were shorter for low than for medium spatial frequency gratings up to contrasts of 0.51. Previous reports of the laten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013