Ultrasound as a feasible method for the assessment of malrotation

نویسندگان

  • Alireza Khatami
  • Kiarash Mahdavi
  • Mohammad Ali Karimi
چکیده

BACKGROUND In malrotation the position of third portion of duodenum (D3) is always intramesenteric. Demonstration of normal retromesenteric-retroperitoneal position of D3 on ultrasound (US) can rule out malrotation. The aim of this study was to evaluate the feasibility of US in demonstrating the retroperitoneal D3. MATERIAL/METHODS Abdominal US study was done for various indications in 60 newborns and infants (mean age: 33 days [range: 4-100 days]; 56.7% male) by an expert pediatric radiologist. The position of D3 and its adjacent structures was evaluated in axial and longitudinal planes by linear and curved transducers. RESULTS A normal retromesenteric-retroperitoneal D3 located between the superior mesenteric artery and the aorta was seen on US in all patients, including those with extensive gas in the bowel. The mean time of D3 observation was 47.8 s (10-180 s). Ultrasound was also capable of demonstrating D3 structure, diameter, content, adjacent structures, relative position of the superior mesenteric artery and vein. CONCLUSIONS Ultrasound is a simple, fast and highly accurate tool to confirm the retroperitoneal position of D3. Ultrasound can be used as a screening method for malrotation eliminating the need for unnecessary barium studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities

Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Comparison of Lecture-based and CD-based Ultrasound and FAST Training for Medical Interns in Emergency Wards

Background: Various training methods such as lecture-based and media-aided methods are employed to train focused assessment with sonography for trauma (FAST) technique during internship period. The current study aimed at comparing the efficacy of lecture-based and CD-based approaches among medical interns in emergency wards. Methods: The current comparati...

متن کامل

Assessment of transvaginal ultrasonography accuracy in the diagnosis of uterine pathologies in women with abnormal uterine bleeding

Abstract Background: The most common causes of abnormal uterine bleeding in women of reproductive age are uterine structural abnormalities. There are several modalities for the examination of abnormal uterine bleeding, including transvaginal ultrasound and hysteroscopy. In this study, we aimed to investigate the diagnostic accuracy of hysteroscopy versus transvaginal ultrasound in the diagnosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 79  شماره 

صفحات  -

تاریخ انتشار 2014