The Best Mothod

نویسندگان

  • Yaowalark Sukthana
  • Ruenruetai Udonsom
چکیده

Although the Sabin-Feldman dye test is the gold standard for detecting Toxoplasma antibodies in human, it is performed only in reference laboratories because live virulent T. gondii are used for the test. We collected 210 human serum samples and tested them by the dye test using in vivo tachyzoites (conventional method) then compared these results with three other methods: a dye test using cell culture-derived T. gondii tachyzoites and indirect immunofluorescent antibody tests (IFAT) using in vivo and in vitro tachyzoites. We found the conventional dye test detected the highest percent of cases (4.3%), followed by the IFAT using parasites from mice (3.8%), then the dye test and the IFAT using cell culture tachyzoites (both 2.8%). Agreement with the dye test when using mouse and cell culture derived tachyzoites was 96.7%. Using in vivo tachyzoites for the dye test and the IFAT gave 94.3% agreement, while using in vitro tachyzoites gave 94.8% agreement. When compared with the conventional dye test, the IFAT had 75% sensitivity and 100% specificity. The T. gondii tachyzoites obtained from cell culture had a lower virulence, as indicated by a three times longer survival period in the inoculated mice. We favor the conventional dye test as the gold standard for Toxoplasma antibody detection. In vitro tachyzoites can be used routinely in the dye test but false negative results may occur in some cases. The IFAT, using either in vivo or in vitro tachyzoites, are alternatives for laboratories where provision of live tachyzoites is limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron identification performance withALICETRDprototypes

We present the electron/pion identification performance measured with prototypes for ALICE TRD. Measured spectra of energy deposit of pions and electrons as well as their average values are presented and compared to calculations. Various radiators are investigated over the momentum range of 1 to 6 GeV/c. The time signature of TR is exploited in a bidimensional likelihood mothod.

متن کامل

RF System Stability Analysis by Simulink on Matlab

Matlab is a widely used software in the field of control. In this paper, we analyze the stability of RF system with it. A RF system is made up of beams, cavities and low level control loops. There are complicated feedback relationships among the phases and amplitudes. In this paper, we present a mothod to analyze the RF control system by Simulink on Matlab. We got some fundamental results. Comp...

متن کامل

A Mothod of Traffic Modeling on Local Area Network for Education

In this paper we propose a method of network traffic modeling that the traffic load of LAN in time is very high. In this method, an individual model of nodes on LAN performs target communication protocols consist of datalink layer and transport/network layers. The model works with the event driven state transition, then we can analyse network traffics with integration of transition times. The s...

متن کامل

بررسی اثر تغییرات کاربری اراضی بر بیابان‌زایی تکنوژنیک در محدودۀ شهر مشهد

Urbanization lead a wide variety of difficulties that changes in the pattern of land use is the major consequence. One of the outcome of land use changes is ecological and biological capacity reduction or desertification. In this study, for determine of desertification due to urban development within the city of Mashhad, was used Iranian mothod (IMDPA). The land use map of this area was prepare...

متن کامل

Relining technique for continuous sac enlargement and modular disconnection secondary to endotension after endovascular aortic aneurysm repair

Endotension is an unpredictable late complication of endovascular aortic aneurysm repair (EVAR). This case report will discuss the successful treatment of enlarged aneurysmal sac due to endotension using the relining technique. An 81-year-old male complained of nondecreasing huge aneurysm sac. He had undergone EVAR for infrarenal abdominal aortic aneurysm 7 years prior and no endoleak was found...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010