A reliability study of colour-Doppler sonography for the diagnosis of chronic cerebrospinal venous insufficiency shows low inter-rater agreement

نویسندگان

  • Maurizio A Leone
  • Olga Raymkulova
  • Ausiliatrice Lucenti
  • Alessandro Stecco
  • Laura Bolamperti
  • Lorenzo Coppo
  • William Liboni
  • Gianandrea Rivadossi
  • Giuseppe Zaccala
  • Maurizio Maggio
  • Fabio Melis
  • Claudia Giaccone
  • Alessandro Carriero
  • Piergiorgio Lochner
چکیده

OBJECTIVE Chronic cerebrospinal venous insufficiency (CCSVI) has been extremely variable, associated with multiple sclerosis in colour-Doppler sonographic studies. We aimed to evaluate inter-rater agreement in a colour-Doppler sonography venous examination. DESIGN Inter-rater agreement study. SETTING First-referral multiple sclerosis centre. PARTICIPANTS 38 patients with multiple sclerosis and 55 age-matched (±5 years) controls. INTERVENTION Sonography was carried out in accordance with Zamboni's five criteria by eight sonographers with different expertise, blinded to the status of cases and controls. Each participant was evaluated by two operators. PRIMARY AND SECONDARY OUTCOME MEASURES Inter-rater agreement was measured through the κ statistics and the intraclass correlation coefficient. RESULTS The agreement was no higher than chance for criterion 2-reflux in the deep cerebral veins (κ=-0.02) and criterion 4-flow not Doppler detectable in one or both the internal jugular veins (IJVs) or vertebral veins (VVs; -0.09). It was substantially low for criterion 1-reflux in the IJVs and/or VVs (0.29), criterion 3-IJV stenosis or malformations (0.23) and criterion 5-absence of IJV diameter increase when passing from the sitting to the supine position (0.22). The κ value for CCSVI as a whole was 0.20 (95% confidence limit -0.01 to 0.42). Intraclass correlation coefficients for the measure of cross-sectional area ranged from 0.05 to 0.25. Inter-rater agreement was low for CCSVI experts (κ=0.24; -0.11 to 0.59) and non-experts (0.20; -0.33 to 0.73); neurologists (0.21; -0.06 to 0.47) and non-neurologists (0.18; -0.20 to 0.56); cases (0.19; -0.14 to 0.52) and controls (0.21; -0.08 to 0.49). Zamboni-trained neurosonographers ascertained CCSVI more frequently than the non-trained neurosonographers. CONCLUSIONS Agreement was unsatisfactory for the diagnosis of CCSVI as a whole, for each of its five criteria and according to the different subgroups. Standardisation of the method is urgently needed prior to its further application in studies of patients with multiple sclerosis or other neurological diseases.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-Retest and Inter-Rater Reliability Study of the Schedule for Oral-Motor Assessment in Persian Children

Objectives: Reliable and valid clinical tools to screen, diagnose, and describe eating functions and dysphagia in children are highly warranted. Today most specialists are aware of the role of assessment scales in the treatment of affected individuals. However, the problem is that the clinical tools used might be nonstandard, and worldwide, there is no integrated assessment performed to assess ...

متن کامل

ارزیابی خطرات محیطی با استفاده از پایایی نسخه فارسی شده ابزار غربالگری زمین خوردن و حوادث در منزل در سالمندان ایرانی

Introduction: one of the common problems among older people is falling. Falling inside the houses and streets makes up a large incidence between Iranian elderly, then the effort to identify environmental factors at home and home modification can reduce falls and injury in the elderly. The aim of this study was identifying elderly at risk of fall with using screening tool (HOME FAST) and deter...

متن کامل

Nurse-Physician Agreement on Triage Category: A Reliability Analysis of Emergency Severity Index

Background and Objectives: MThe Emergency Severity Index (ESI) triage is commonly used in clinical settings to determine the patients’ emergency severity. However, the reliability of this index is not sufficiently explored. The present study examines the inter-rater reliability of ESI by comparing triage ratings as performed by nurses and physicians. Methods: This prospective cross-sectional st...

متن کامل

Development and assessment of inter- and intra-rater reliability of a novel ultrasound tool for scoring tendon and sheath disease - A pilot study.

BACKGROUND Tendon and synovial sheath disease is common. A method of monitoring the status of tendons and sheaths is important for both diagnosis of pathology and evaluation of the efficacy of treatments. For this study, an ultrasound scoring tool was developed and its reliability tested between raters. The tool is novel in that it scores tendons and sheaths separately, an important considerati...

متن کامل

Functional Movement Screen in Elite Boy Basketball Players: A Reliability Study

Purpose: To investigate the reliability of Functional Movement Screen (FMS) in basketball players. A few studies have compared the reliability of FMS between raters with different experience in athletes. The purpose of this study was to compare the FMS scoring between the beginners and expert raters using video records.  Methods: This is a cross-sectional study. The study subjects compris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013