Dual effects of acupuncture on gastric motility in conscious rats.

نویسندگان

  • Makoto Tatewaki
  • Mary Harris
  • Kenichiro Uemura
  • Tomio Ueno
  • Etsuo Hoshino
  • Akiko Shiotani
  • Theodore N Pappas
  • Toku Takahashi
چکیده

The effects of manual acupuncture on gastric motility were investigated in 35 conscious rats implanted with a strain gauge transducer. Twenty (57.1%) rats showed no cyclic groupings of strong contractions (type A), whereas 15 (42.9%) rats showed the phase III-like contractions of the migrating motor complex (type B) in the fasting gastric motility. Acupuncture at the stomach (ST)-36 (Zusanli), but not on the back [Weishu, bladder (BL)-21], increased the peak amplitude of contractions to 172.4 +/- 25.6% of basal in the type A rats (n = 20, P < 0.05). On the other hand, the motility index for 60 min after the acupuncture was not affected by the acupuncture in this group. On the contrary, acupuncture decreased the peak amplitude and motility index to 72.9 +/- 14.0% and 73.6 +/- 16.2% in the type B rats (n = 15, P < 0.05), respectively. The stimulatory and inhibitory effects of acupuncture observed in each type were reproducible on the separate days. In 70% of type A rats, acupuncture induced strong phase III-like contractions lasting for over 3 h that were abolished by atropine, hexamethonium, atropine methyl bromide, and vagotomy. Naloxone significantly shortened the duration of the stimulatory effects from 3.52 +/- 0.21 to 1.02 +/- 0.15 h (n = 3, P < 0.05). These results suggest that acupuncture at ST-36 induces dual effects, either stimulatory or inhibitory, on gastric motility. The stimulatory effects are mediated in part via vagal efferent and opioid pathways.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manual Acupuncture and Laser Acupuncture for Autonomic Regulations in Rats: Observation on Heart Rate Variability and Gastric Motility

This study focused on the effects of laser acupuncture (LA) and manual acupuncture (MA) at different acupoints on gastric motility and heart rate variability (HRV) simultaneously to elucidate the site specific effects of acupoints and the correlation between changes of gastric motility and low frequency/high frequency (LF/HF) ratio. Gastric motility and HRV were recorded before and during MA or...

متن کامل

In vivo and in vitro effects of Salsola collina on gastrointestinal motility in rats

Objective(s): Salsola collina is widely distributed along the Bohai coast and consumed as an edible plant by native residents. We have found surprisingly that S. collina extracts promoted gastrointestinal motility in mice previously. In the present study, effects of S. collina on gastrointestinal motility in rats and its underlying mechanism were explored.<st...

متن کامل

The Effects of Achillea wilhelmsii Extract on Rat’s Gastric Motility at Basal and Vagal Stimulated Conditions

Objective(s) Achillea genius is widely used in traditional medicine for gastrointestinal disorders. The aim of this study was to investigate the effects of aqueous-ethanol extract of Achillea wilhelmsii on rat’s gastric motility in basal and vagal stimulated conditions. Materials and Methods Twenty four Wistar rats were randomly divided into two groups: control and test. The extract was prep...

متن کامل

Acupuncture at homotopic acupoints exerts dual effects on bladder motility in anesthetized rats

BACKGROUND In Chinese medicine, dual effects on target organs are considered a primary characteristic of acupoint. Acupoints may be classified as heterotopic or homotopic in terms of spinal segmental innervation: homotopic acupoints contain afferent innervation in the same segment from which efferent fibers innervate target visceral organs, and heterotopic acupoints utilize different spinal seg...

متن کامل

Somatosensory Nerve Fibers Mediated Generation of De-qi in Manual Acupuncture and Local Moxibustion-Like Stimuli-Modulated Gastric Motility in Rats

The aim of this study was to reveal the somatosensory nerve fibers mediated generation of De-qi in manual acupuncture stimuli (MAS) and local moxibustion-like stimuli (LMS). The effects of strong and slight MAS, as well as 41°C, 43°C, and 45°C LMS at ST36 and CV12 on gastric motility were observed in rats. Gastric motility was continuously measured by an intrapyloric balloon, and the average am...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Regulatory, integrative and comparative physiology

دوره 285 4  شماره 

صفحات  -

تاریخ انتشار 2003