A robotic case study: optimal design for laparoscopic positioning stands

نویسندگان

  • Ali Faraz
  • Shahram Payandeh
چکیده

The positioning stand could help the surgeon to position and lock endoscopic tools without the need for an assistant surgeon. The kinematic con guration of the positioning stand is comprised of two main parts, the arm (for positioning) and the wrist (for orienting the tool). The main requirement of the wrist is to perform spherical movements around the incision point. A concentric multi-link spherical joint design has been developed for the wrist mechanism. The size synthesis is performed to minimize the overall size of wrist and also to maximize its range of angular movements. The type synthesis of the positioning arm has led to SCARA con guration, as a balanced and easy to move arm con guration. The size synthesis of the arm is carried out with the goal of minimizing its overall dimensions, based on reachable workspace and manipulability of the arm. The integration of the wrist and arm is performed by optimizing the orientation of wrist in such a way that the interference between the wrist and the workspace of surgeon is minimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Port Placement And Automated Robotic Positioning For Instrumented Laparoscopic Biosensors

........................................................................................................................... 128 Autobiographical Statement .............................................................................................. 130

متن کامل

Totally robotic Roux-en-Y gastric bypass.

HYPOTHESIS We hypothesized that we could develop a safe and effective technique for performing a totally robotic laparoscopic Roux-en-Y gastric bypass procedure using the da Vinci surgical system. We anticipated that the learning curve for this totally robotic procedure could be shorter than the learning curve for standard laparoscopic bariatric surgery. DESIGN Retrospective case comparison s...

متن کامل

Are Autonomous Mobile Robots Able to Take Over Construction? A Review

Although construction has been known as a highly complex application field for autonomous robotic systems, recent advances in this field offer great hope for using robotic capabilities to develop automated construction. Today, space research agencies seek to build infrastructures without human intervention, and construction companies look to robots with the potential to improve construction qua...

متن کامل

Robotic “Side Hole” Technique Placement of Ureteral Stent for Ureteral Lesion

A 67-year-old patient underwent robotic-assisted laparoscopic radical prostatectomy and experienced right ureteral lesion. The laceration was recognized intraoperatively and immediately repaired over the ureteral double J stent. The wire and the stent were first advanced distally to the bladder. Then the wire was pulled with its soft end, cranially through one of the side holes of the proximal ...

متن کامل

Postural ergonomics during robotic and laparoscopic gastric bypass surgery: a pilot project

We hypothesized that a laparoscopic technique for Roux-en-Y gastric bypass surgery is associated with more musculoskeletal discomfort and ergonomic strain than a robotic technique. This pilot project studied one surgeon while he performed four laparoscopic and four robotic (da Vinci system) Roux-en-Y gastric bypass procedures. We measured musculoskeletal discomfort with body part discomfort sco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • I. J. Robotics Res.

دوره 17  شماره 

صفحات  -

تاریخ انتشار 1997