New Method for Separation of Electrode Polarization Impedance from Measured Tissue Impedance
نویسندگان
چکیده
In this paper we have shown that electrode polarization impedance (EPI) can be separated from measured tissue impedance as long as the characteristic frequencies of EPI and tissue are not too close, so that the EPI is largely displayed as a separate dispersion. In 2-electrode measurements the EPI and sample are physically connected in series, and commonly modelled by equivalent components in series. We have calculated the parallel equivalent elements and converted the series connected EPI and sample to a parallel admittance model. By curve fitting on the converted model we have shown that this provides a new method for estimating the EPI with enhanced accuracy compared to similar techniques used on the impedance model.
منابع مشابه
The Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges
Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...
متن کاملImpedance-based tissue discrimination for needle guidance.
Measurement of electrical impedance can discriminate between tissues of different electrical properties. A measurement system with adequate spatial resolution focused on a volume around the tip of a needle or other invasive clinical equipment can be used to determine in which type of tissue the tip is positioned. We have measured the sensitivity zone of a needle electrode with an active electro...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملEffects of Stray Capacitance to Ground in Bipolar Water Impedance Measurements Based on Capacitive Electrodes
Liquid impedance measurements based on capacitive (or contactless) electrodes overcome electrode polarization problems but are affected by stray capacitance from the material being measured to ground, the same as measurements with direct-contact electrodes. This study shows that the effects of that capacitance depend on the impedance being measured and for bipolar impedance measurements they ...
متن کاملCorrecting the polarization effect in very low frequency dielectric spectroscopy
Polarization impedance appears at the interface between electrodes and ionic solutions and is a major source of errors in dielectric spectroscopy measurements. This work presents a simple, robust and automated methodology for measuring and analysing the polarization impedance of non-dispersive electrolytes, with a focus on the very low frequency domain from 1 Hz and up. The accuracy of the meth...