Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO

نویسندگان

  • F Gilbert
  • L Eden
  • R Meffert
  • F Konietschke
  • J Lotz
  • L Bauer
  • W Staab
چکیده

BACKGROUND Representing 3%-5% of shoulder girdle injuries scapula fractures are rare. Furthermore, approximately 1% of scapula fractures are intraarticularfractures of the glenoid fossa. Because of uncertain fracture morphology and limited experience, the treatment of glenoid fossa fractures is difficult. The glenoid fracture classification by Ideberg (1984) and Euler (1996) is still commonly used in literature. In 2013 a new glenoid fracture classification was introduced by the AO. The purpose of this study was to examine the new AO classification in clinical practice in comparison with the classifications by Ideberg and Euler. METHODS In total CT images of 84 patients with glenoid fossa fractures from 2005 to 2018 were included. Parasagittal, paracoronary and axial reconstructions were examined according to the classifications of Ideberg, Euler and the AO by 3 investigators (orthopedic surgeon, radiologist, student of medicine) at three individual time settings. Inter- and intraobserver reliability of the three classification systems were ascertained by computing Inter- and Intraclass (ICCs) correlation coefficients using Spearman's rank correlation coefficient, 95%-confidence intervals as well as F-tests for correlation coefficients. RESULTS Inter- and intraobserver reliability for the AO classification showed a perspicuous coherence (R = 0.74 and R = 0.79). Low to moderate intraobserver reliability for Ideberg (R = 0.46) and Euler classification (R = 0.41) was found. Furthermore, data show a low Interobserver reliability for both Ideberg and Euler classification (R < 0.2). Both the Inter- and Intraclass reliability using AO is significantly higher than those using Ideberg and Euler (p < 0.05). Using the new AO classification, it was possible to find a proper class for every glenoid fossa fracture. On average, according to Euler classification 10 of 84 fractures were not classifiable whereas to Ideberg classification 21 of 84 fractures were not classifiable. CONCLUSION The new AO classification system introduced 2013 facilitates reliable grading of glenoid fossa fractures with high inter- and intraobserver reliability in 84 patients using CT images. It should possibly be applied in order to enable a valid, reliable and consistent academic description of glenoid fossa fractures. The established classifications by Euler and Ideberg are not capable of providing a similar reliability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Arthroscopy Assisted Percutaneous Fixation of Ideberg Type Iii Glenoid Fractures

INTRODUCTION Intra-articular glenoid fractures are extremely rare and may be associated with other injuries. Traditionally open reduction and internal fixation has been recommended in displaced intra-articular glenoid fractures. However open reduction is difficult and it may not be possible to address the associated intra-articular soft tissue injuries. A few reports of arthroscopic assisted fi...

متن کامل

Acromial approach for treating glenoid fractures: A report of two cases and a literature review

Surgery is usually recommended for displaced glenoid fractures, with open reduction and internal fixation as the standard operative treatment. Three approaches have been recommended in the reduction of glenoid fractures: Anterior, posterior and combined; however, a traditional approach may be difficult due to a high position or a comminuted Ideberg type III fracture. The combined approach resul...

متن کامل

Reproducibility of the AO/ASIF and Gartland classifications for supracondylar fractures of the humerus in children☆

OBJECTIVE To evaluate the reproducibility of the radiographic classifications of Gartland and the Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) for supracondylar fractures of the humerus in children. METHODS On two occasions, 50 radiographs in anteroposterior and lateral views were evaluated by three pediatric orthopedists in accordance with the Gartl...

متن کامل

Are distal radius fracture classifications reproducible? Intra and interobserver agreement.

CONTEXT AND OBJECTIVE Various classification systems have been proposed for fractures of the distal radius, but the reliability of these classifications is seldom addressed. For a fracture classification to be useful, it must provide prognostic significance, interobserver reliability and intraobserver reproducibility. The aim here was to evaluate the intraobserver and interobserver agreement of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018